Robotic Totally Endoscopic Triple Coronary Artery Bypass Grafting on the Arrested Heart: Report of the First Successful Clinical Case

被引:13
作者
Bonatti, Johannes [1 ]
Rehman, Atiq [1 ]
Schwartz, Kimberly [1 ]
Deshpande, Seema [1 ]
Kon, Zachary [1 ]
Lehr, Eric [1 ]
Zimrin, David [1 ]
Griffith, Bartley [1 ]
机构
[1] Univ Maryland, Dept Surg, Div Cardiac Surg, Sch Med, Baltimore, MD 21201 USA
关键词
SAFETY;
D O I
10.1532/HSF98.20101143
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
Robotic technology enables "port only" totally endoscopic coronary artery bypass grafting (TECAB). During early procedure development only single bypass grafts were feasible. Because current referral practice for coronary bypass surgery mostly includes multivessel disease, performance of multiple endoscopic bypass grafts is desirable. We report a case in which a patient received a right internal mammary artery bypass graft to the left anterior descending artery and a left internal mammary artery jump graft to 2 obtuse marginal branches. The procedure was performed through 5 ports on the arrested heart using the daVinci S robotic surgical system. This is the first reported triple bypass grafting procedure using an arrested heart approach.
引用
收藏
页码:E394 / E396
页数:3
相关论文
共 8 条
[1]
Bonatti Johannes, 2006, Interact Cardiovasc Thorac Surg, V5, P279, DOI 10.1510/icvts.2005.123125
[2]
Robotic totally endoscopic double-vessel bypass grafting:: A further step toward closed-chest surgical treatment of multivessel coronary artery disease [J].
Bonatti, Johannes ;
Schachner, Thomas ;
Bonaros, Nikolaos ;
Oehlinger, Armin ;
Ruetzler, Elisabeth ;
Feuchtner, Gudrun ;
Kolbitsch, Christian ;
Friedrich, Guy ;
Bartel, Thomas ;
Pachinger, Otmar ;
Laufer, Guenther .
HEART SURGERY FORUM, 2007, 10 (03) :E239-E242
[3]
Effectiveness and Safety of Total Endoscopic Left Internal Mammary Artery Bypass Graft to the Left Anterior Descending Artery [J].
Bonatti, Johannes ;
Schachner, Thomas ;
Bonaros, Nikolaos ;
Oehlinger, Armin ;
Wiedemann, Dominik ;
Ruetzler, Elisabeth ;
Weidinger, Felix ;
Kolbitsch, Christian ;
Feuchtner, Gudrun ;
Zimrin, David ;
Friedrich, Guy ;
Pachinger, Otmar ;
Laufer, Guenther .
AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (12) :1684-1688
[4]
Feasibility, safety, and efficacy of totally endoscopic coronary artery bypass grafting: Multicenter European experience [J].
de Canniere, Didier ;
Wimmer-Greinecker, Gerhard ;
Cichon, Romuald ;
Gulielmos, Vassilios ;
Van Praet, Frank ;
Seshadri-Kreaden, Usha ;
Falk, Volkmar .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2007, 134 (03) :710-716
[5]
Totally endoscopic coronary artery bypass grafting on cardiopulmonary bypass with robotically enhanced telemanipulation: Report of forty-five cases [J].
Dogan, S ;
Aybek, T ;
Andressen, E ;
Byhahn, C ;
Mierdl, S ;
Westphal, K ;
Matheis, G ;
Moritz, A ;
Wimmer-Greinecker, G .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 123 (06) :1125-1131
[6]
Total endoscopic computer enhanced coronary artery bypass grafting [J].
Falk, V ;
Diegeler, A ;
Walther, T ;
Banusch, J ;
Brucerius, J ;
Raumans, J ;
Autschbach, R ;
Mohr, FW .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2000, 17 (01) :38-45
[7]
Myocardial enzyme release in totally endoscopic coronary artery bypass grafting on the arrested heart [J].
Schachner, Thomas ;
Bonaros, Nikolaos ;
Ruetzler, Elisabeth ;
Weidinger, Felix ;
Oehlinger, Armin ;
Laufer, Guenther ;
Friedrich, Guy ;
Bonatti, Johannes .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2007, 134 (04) :1006-1011
[8]
Beating Heart Totally Endoscopic Coronary Artery Bypass [J].
Srivastava, Sudhir ;
Gadasalli, Suresh ;
Agusala, Madhava ;
Kolluru, Ram ;
Barrera, Reyna ;
Quismundo, Shaune ;
Kreaden, Usha ;
Jeevanandam, Valluvan .
ANNALS OF THORACIC SURGERY, 2010, 89 (06) :1873-1880