Bioreconstructive joint scaffold implant arthroplasty in metacarpophalangeal joints:: Short-term results of a new treatment concept in rheumatoid arthritis patients

被引:36
作者
Honkanen, PB
Kellomäki, M
Lehtimäki, MY
Törmälä, P
Mäkelä, S
Lehto, MUK
机构
[1] Tampere Univ Hosp, Dept Surg, Div Orthoped, Tampere 33521, Finland
[2] Tampere Univ Hosp, Dept Psychiat, Tampere 33521, Finland
[3] Univ Tampere, Sch Med, FIN-33101 Tampere, Finland
[4] Tampere Univ Technol, Inst Biomat, FIN-33101 Tampere, Finland
[5] Coxa, Hosp Joint Replacement, Tampere, Finland
来源
TISSUE ENGINEERING | 2003年 / 9卷 / 05期
关键词
D O I
10.1089/107632703322495600
中图分类号
Q813 [细胞工程];
学科分类号
摘要
Swanson silicone implant is the "gold standard" of metacarpophalangeal joint reconstruction in rheumatoid arthritis (RA) patients. However, durability problems of silicone implants have led us to develop a new technique based on bioreconstructive implants. PLA96 (poly-L,D-lactide copolymer, L:D ratio of 96:4) scaffolds were engineered. Bioabsorption and substitution of porous PLA96 scaffold with living tissue eventually produce a neojoint. In the current prospective study, 23 RA patients (80 joints) were operated on, using PLA96 implants. Fifteen patients (54 joints) have been monitored for at least 1 year. Pain alleviation was well achieved. Range of motion improvement was emphasized to extension direction of functional arc. The average ulnar deviation was preoperatively 26degrees, and at follow-up it was 6degrees. Volar subluxation was noticeable in 56% of joints preoperatively and in 6% at 1-year follow-up. This is the first report of the formation of a living, functional joint in situ by means of a synthetic bioreconstructive joint scaffold. Results of this preliminary short-term study are comparable with previously published data on silicone arthroplasty. However, bioreconstructive prostheses can aid in preventing problems that occur with biostable prostheses. Tissue engineering has created a new era in the reconstruction of damaged joints.
引用
收藏
页码:957 / 965
页数:9
相关论文
共 17 条
[1]
ALLIEU Y, 1998, RHEUMATOID HAND WRIS
[2]
High implant fracture incidence with Sutter silicone metacarpophalangeal joint arthroplasty [J].
Bass, RL ;
Stern, PJ ;
Nairus, JG .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1996, 21A (05) :813-818
[3]
Beckenbaugh RD, 1999, ACTA ORTHOP SCAND, V70, P107
[4]
Chung KC, 2000, J RHEUMATOL, V27, P1395
[5]
KELLOMAKI M, 2002, S TISS ENG SCI CRIT
[6]
KELLOMAKI M, 2000, MATER ENG, V2, P73
[7]
RADIOGRAPHIC EVALUATION OF RHEUMATOID-ARTHRITIS AND RELATED CONDITIONS BY STANDARD REFERENCE FILMS [J].
LARSEN, A ;
DALE, K ;
EEK, M .
ACTA RADIOLOGICA-DIAGNOSIS, 1977, 18 (04) :481-491
[8]
Lehtimaki M., 1998, SCAND HAND SOC M OSL
[9]
Implant arthroplasty of the hand: Retrospective and prospective considerations [J].
Linscheid, RL .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2000, 25A (05) :796-816
[10]
RELIABILITY AND VALIDITY OF GRIP AND PINCH STRENGTH EVALUATIONS [J].
MATHIOWETZ, V ;
WEBER, K ;
VOLLAND, G ;
KASHMAN, N .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1984, 9A (02) :222-226