Solute washout experiments for characterizing mass transport in hollow fiber immunoisolation membranes

被引:12
作者
Boyd, RF
Lopez, M
Stephens, CL
Velez, GM
Ramirez, CA
Zydney, AL [1 ]
机构
[1] Univ Delaware, Dept Chem Engn, Newark, DE 19716 USA
[2] Univ Puerto Rico, Dept Chem Engn, Mayaguez, PR USA
基金
美国国家科学基金会;
关键词
artificial organs; immunoisolation; membrane transport; diffusion; hollow fiber membranes; solute washout; hybrid artificial pancreas;
D O I
10.1114/1.102
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The transport characteristics of immunoisolation membranes can have a critical effect on the design of hybrid artificial organs and cell therapies. However, it has been difficult to quantitatively evaluate the desired transport properties of different hollow fiber membranes due to bulk mass transfer limitations in the fiber lumen and annular space. An attractive alternative to existing methodologies is to use the rate of solute removal or "washout" from the annular space during constant flow perfusion through the fiber lumen. Experimental washout curves were obtained for glucose and a 10 kD dextran in two different hollow fiber devices. Data were analyzed using a theoretical model which accounts for convective and diffusive transport in the lumen, membrane, and annular space. The model was in good agreement with the experimental results and provided an accurate measure of the effective membrane diffusion coefficient for both small and large solutes. This approach should prove useful in theoretical analyses of solute transport and performance of hollow fiber artificial organs. (C) 1998 Biomedical Engineering Society.
引用
收藏
页码:618 / 626
页数:9
相关论文
共 23 条
[1]   TRANSPLANTATION IN HUMANS OF ENCAPSULATED XENOGENEIC CELLS WITHOUT IMMUNOSUPPRESSION - A PRELIMINARY-REPORT [J].
AEBISCHER, P ;
BUCHSER, E ;
JOSEPH, JM ;
FAVRE, J ;
DETRIBOLET, N ;
LYSAGHT, M ;
RUDNICK, S ;
GODDARD, M .
TRANSPLANTATION, 1994, 58 (11) :1275-1277
[2]   Modeling of axial-flow hollow fiber cell culture bioreactors [J].
Brotherton, JD ;
Chau, PC .
BIOTECHNOLOGY PROGRESS, 1996, 12 (05) :575-590
[3]   Mass transfer limitations to the performance of membrane bioartificial liver support devices [J].
Catapano, G .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1996, 19 (01) :18-35
[4]   BETA CELL-CULTURE ON SYNTHETIC CAPILLARIES - ARTIFICIAL ENDOCRINE PANCREAS [J].
CHICK, WL ;
LIKE, AA ;
LAURIS, V .
SCIENCE, 1975, 187 (4179) :847-849
[5]   BIOENGINEERING IN DEVELOPMENT OF THE HYBRID ARTIFICIAL PANCREAS [J].
COLTON, CK ;
AVGOUSTINIATOS, ES .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1991, 113 (02) :152-170
[6]  
COLTON CK, 1981, KIDNEY, P2425
[7]   HINDERED TRANSPORT OF LARGE MOLECULES IN LIQUID-FILLED PORES [J].
DEEN, WM .
AICHE JOURNAL, 1987, 33 (09) :1409-1425
[8]   Transport characterization of membranes for immunoisolation [J].
Dionne, KE ;
Cain, BM ;
Li, RH ;
Bell, WJ ;
Doherty, EJ ;
Rein, DH ;
Lysaght, MJ ;
Gentile, FT .
BIOMATERIALS, 1996, 17 (03) :257-266
[9]  
Giorgio T D, 1993, ASAIO J, V39, P886, DOI 10.1097/00002480-199310000-00012
[10]  
Granath KA, 1958, J COLLOID SCI, V13, P308, DOI DOI 10.1016/0095-8522(58)90041-2