A comparative study of pure and zeotropic mixtures in low-temperature solar Rankine cycle

被引:224
作者
Wang, J. L. [1 ]
Zhao, L. [1 ]
Wang, X. D. [1 ]
机构
[1] Tianjin Univ, Sch Mech Engn, Dept Thermal Energy & Refrigerat Engn, Tianjin 300072, Peoples R China
关键词
Zeotropic mixture; Rankine cycle; Solar; Low temperature; WORKING FLUIDS; PERFORMANCE; SYSTEM; POWER; ORC;
D O I
10.1016/j.apenergy.2010.05.016
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The paper presents an on site experimental study of a low-temperature solar Rankine cycle system for power generation. The cycle performances of pure fluid M-1 (R245fa) and zeotropic mixtures M-2 (R245fa/R152a, 0.9/0.1) and M-3 (R245fa/R152a, 0.7/0.3) are compared, respectively, based on the experimental prototype. The experiments have been conducted under constant volume flow rate of different fluids. The results show that, with the component of R152a increasing, the system pressure level increases and the power output varies accordingly, which provides an additional means of capacity adjustment. The collector efficiency and thermal efficiency of zeotropic mixtures are comparatively higher than pure fluid of R245fa in the experimental condition, which indicates that zeotropic mixtures have the potential for overall efficiency improvement. Due to the non-isothermal condensation of zeotropic mixture, the condensing heat could be partially recovered by adding an external heat exchanger. Thus, compared with pure fluid R245fa the system overall efficiency of zeotropic mixtures could be improved. Crown Copyright (C) 2010 Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:3366 / 3373
页数:8
相关论文
共 26 条
[1]   Multicomponent working fluids for organic rankine cycles (ORCs) [J].
Angelino, G ;
Di Paliano, PC .
ENERGY, 1998, 23 (06) :449-463
[2]   Comparative analysis of natural and synthetic refrigerants in application to low temperature Clausius-Rankine cycle [J].
Borsukiewicz-Gozdur, Aleksandra ;
Nowak, Wladyslaw .
ENERGY, 2007, 32 (04) :344-352
[3]   Alternative ORC bottoming cycles FOR combined cycle power plants [J].
Chacartegui, R. ;
Sanchez, D. ;
Munoz, J. M. ;
Sanchez, T. .
APPLIED ENERGY, 2009, 86 (10) :2162-2170
[4]   Fluid selection for the Organic Rankine Cycle (ORC) in biomass power and heat plants [J].
Drescher, Ulli ;
Brueggemann, Dieter .
APPLIED THERMAL ENGINEERING, 2007, 27 (01) :223-228
[5]  
EMMANUEL C, 2009, APPL ENERG, V86, P1055
[6]   Optimum design criteria for an Organic Rankine cycle using low-temperature geothermal heat sources [J].
Hettiarachchia, H. D. Madhawa ;
Golubovica, Mihajlo ;
Worek, William M. ;
Ikegami, Yasuyuki .
ENERGY, 2007, 32 (09) :1698-1706
[7]   A review of organic Rankine cycles (ORCs) for the recovery of low-grade waste heat [J].
Hung, TC ;
Shai, TY ;
Wang, SK .
ENERGY, 1997, 22 (07) :661-667
[8]  
Lemmon EW, 2007, REFERENCE FLUID THER
[9]   Effect of working fluids on organic Rankine cycle for waste heat recovery [J].
Liu, BT ;
Chien, KH ;
Wang, CC .
ENERGY, 2004, 29 (08) :1207-1217
[10]   An examination of regenerative organic Rankine cycles using dry fluids [J].
Mago, Pedro J. ;
Chamra, Louay M. ;
Srinivasan, Kalyan ;
Somayaji, Chandramohan .
APPLIED THERMAL ENGINEERING, 2008, 28 (8-9) :998-1007