The thermoluminescence of Toshiba FD-1 and FD-7 RPL glass

被引:6
作者
Croft, S
Weaver, DR
Matthews, R
机构
关键词
D O I
10.1093/oxfordjournals.rpd.a031666
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The thermoluminescent response of Toshiba FD-1 and Toshiba FD-7 radiophotoluminescent dosimetry glass to Co-60 gamma radiation has been studied at doses of up to 66 kGy air kerma and 590 kGy air kerma respectively. The FD-1 glass was in the form of rods 1 mm in diameter by 6 mm long whereas the FD-7 glass was in the form of blocks of 4.6 mm square and 1.47 mm thick. The FD-1 rods had a pre-dose signal equivalent to 180 Gy and were useable up to the maximum dose studied although the response-dose curve was slightly supralinear at low doses. The FD-7 samples had a predose of 6.2 Gy and began to show severe saturation beyond about 1 kGy. The specific TL efficiencies (counts.mg.(-1).Gy(-1)) of the two glass types have been compared with LiF and BeO and found to be some six orders of magnitude lower.
引用
收藏
页码:381 / 384
页数:4
相关论文
共 15 条
[1]  
Bohm M., 1984, Radiation Protection Dosimetry, V8, P139
[2]  
CROFT S, 1990, RADIAT PROT DOSIM, V33, P355
[3]  
CROFT S, 1990, RADIAT PROT DOSIM, V33, P183
[4]  
CROFT S, 1989, RADIAT PROT DOSIM, V27, P251
[5]   THE PHOTON ENERGY-DEPENDENCE OF RADIOPHOTOLUMINESCENT GLASS DOSIMETERS OVER THE RANGE 17 KEV TO 6.8 MEV [J].
CROFT, S ;
WEAVER, DR .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 280 (01) :123-132
[6]   THE THERMAL-NEUTRON SENSITIVITIES OF SEI AND TOSHIBA FD-P10-7 RADIOPHOTOLUMINESCENT GLASS DOSIMETERS [J].
CROFT, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 286 (1-2) :270-278
[7]  
CROFT S, 1986, RADIAT PROT DOSIM, V17, P67
[8]  
CROFT S, 1992, APPL RADIAT ISOTOPES, V43, P605, DOI 10.1016/0883-2889(92)90027-C
[9]  
FREYTAG E, 1971, HEALTH PHYS, V20, P93
[10]  
LEWIS TA, 1983, TPRDB0349N83 CTR EL