Expanded polytetrafluoroethylene membranes to wrap surfaces of circulatory support devices in patients undergoing bridge to heart transplantation

被引:30
作者
Leprince, P [1 ]
Rahmati, M [1 ]
Bonnet, N [1 ]
Bors, V [1 ]
Rama, A [1 ]
Léger, P [1 ]
Gandjbakhch, I [1 ]
Pavie, A [1 ]
机构
[1] Grp Hosp Pitie Salpetriere, Serv Chirurg Thorac & Cardiovasc, F-75651 Paris 13, France
关键词
left ventricular assist device; total artificial heart; expanded polytetrafluoroethylene; pericardial substitute; adhesions;
D O I
10.1016/S1010-7940(01)00593-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Because of a lack of donor hearts, an increasing number of patients with heart failure must now undergo bridge to cardiac transplantation with a mechanical circulatory support device. Moreover, support periods have become longer. As a result, pericardial adhesions may develop while the support device is implanted, increasing the risk of injury at resternotomy and bleeding after transplantation. Use of expanded polytetrafluoroethylene (ePTFE) pericardial substitutes (membranes) may prevent such adhesions. Patients and methods: From January 1997 to December 1999, ePTFE membranes were used in 23 patients to wrap portions of an implanted left ventricular assist device (LVAD) or total artificial heart (TAH). Any complications during mechanical support or at cardiac transplantation were recorded. Six ePTFE membranes removed at transplantation were studied histologically. Results and conclusions: At resternotomy for transplantation, the plane of dissection between tissues, ePTFE membranes, and surfaces of the mechanical support device were easily discerned. No adhesions were observed between tissues and membranes. There were no injuries during resternotomy and no patient had to undergo reoperation because of bleeding. One patient given a TAH had an infection during circulatory support that was controlled by antibiotic therapy. In another patient, clots developed between the device and an ePTFE membrane; these were removed successfully. Histologic studies of removed ePTFE membranes showed no infiltration of the membranes interstices by collagen or cellular components. Use of ePTFE membranes in patients undergoing bridge to transplantation with either an LVAD or a TAH limited adhesions between tissues and device surfaces without increasing the risk of infection. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:302 / 306
页数:5
相关论文
共 16 条
[1]  
AMATO JJ, 1989, J THORAC CARDIOV SUR, V97, P929
[2]  
Bhatnagar G, 1998, J CARDIAC SURG, V13, P190
[3]  
BUNTON RW, 1990, J THORAC CARDIOV SUR, V100, P99
[4]   Medical progress - Implantable left ventricular assist devices [J].
Goldstein, DJ ;
Oz, MC ;
Rose, EA .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (21) :1522-1533
[5]  
HARADA Y, 1988, J THORAC CARDIOV SUR, V96, P811
[6]   PERICARDIAL SUBSTITUTES - A SURVEY [J].
HEYDORN, WH ;
FERRARIS, VA ;
BERRY, WR .
ANNALS OF THORACIC SURGERY, 1988, 46 (05) :567-569
[7]   Infection during circulatory support with ventricular assist devices [J].
Holman, WL ;
Skinner, JL ;
Waites, KB ;
Benza, RL ;
McGiffin, DC ;
Kirklin, JK .
ANNALS OF THORACIC SURGERY, 1999, 68 (02) :711-716
[8]   USE OF EXPANDED POLYTETRAFLUOROETHYLENE PERICARDIAL SUBSTITUTE WITH VENTRICULAR ASSIST DEVICES [J].
HOLMAN, WL ;
BOURGE, RC ;
ZORN, GL ;
BRANTLEY, LH ;
KIRKLIN, JK .
ANNALS OF THORACIC SURGERY, 1993, 55 (01) :181-183
[9]   Expanded PTFE membrane to prevent cardiac injury during resternotomy for congenital heart disease [J].
Jacobs, JP ;
Iyer, RS ;
Weston, JS ;
Amato, JJ ;
Elliott, MJ ;
deLeval, MR ;
Stark, J .
ANNALS OF THORACIC SURGERY, 1996, 62 (06) :1778-1782
[10]   Computed tomographic evaluation of retrosternal adhesions after pericardial substitution [J].
Lahtinen, J ;
Satta, J ;
Lähde, S ;
Suramo, I ;
Nissinen, J ;
Pokela, R ;
Juvonen, T .
ANNALS OF THORACIC SURGERY, 1998, 66 (04) :1264-1268