Efficient computer-aided detection of ground-glass opacity nodules in thoracic CT images

被引:17
作者
Ye, Xujiong [1 ]
Lin, Xinyu [1 ]
Beddoe, Gareth [1 ]
Dehmeshki, Jamshid [1 ]
机构
[1] Medicsight PLC, London W14 8UD, England
来源
2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16 | 2007年
关键词
D O I
10.1109/IEMBS.2007.4353326
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this paper, an efficient compute-aided detection method is proposed for detecting Ground-Glass Opacity (GGO) nodules in thoracic CT images. GGOs represent a clinically important type of lung nodule which are ignored by many existing CAD systems. Anti-geometric diffusion is used as preprocessing to remove image noise. Geometric shape features (such as shape index and dot enhancement), are calculated for each voxel within the lung area to extract potential nodule concentrations. Rule based filtering is then applied to remove False Positive regions. The proposed method has been validated on a clinical dataset of 50 thoracic CT scans that contains 52 GGO nodules. A total of 48 nodules were correctly detected and resulted in an average detection rate of 92.3%, with the number of false positives at approximately 12.7/scan (0.07/slice). The high detection performance of the method suggested promising potential for clinical applications.
引用
收藏
页码:4449 / 4452
页数:4
相关论文
共 14 条
[1]   Automated detection of lung nodules in CT scans: Preliminary results [J].
Armato, SG ;
Giger, ML ;
MacMahon, H .
MEDICAL PHYSICS, 2001, 28 (08) :1552-1561
[2]   Automatic detection of lung nodules from multi-slice low-dose CT images [J].
Fan, L ;
Novak, CL ;
Qian, JZ ;
Kohl, G ;
Naidich, DP .
MEDICAL IMAGING: 2001: IMAGE PROCESSING, PTS 1-3, 2001, 4322 :1828-1835
[3]  
Gonzalez R., 2019, Digital Image Processing, V2nd
[4]  
HAMID R, 1997, FUZZY IMAGE PROCESSI
[5]  
KIM H, 2005, P INT TOOLS ART INT
[6]   Automated detection of pulmonary nodules in helical CT images based on an improved template-matching technique [J].
Lee, Y ;
Hara, T ;
Fujita, H ;
Itoh, S ;
Ishigaki, T .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (07) :595-604
[7]   Selective enhancement filters for nodules, vessels, and airway walls in two- and three-dimensional CT scans [J].
Li, Q ;
Sone, S ;
Doi, K .
MEDICAL PHYSICS, 2003, 30 (08) :2040-2051
[8]   Object-based deformation technique for 3-D CT lung nodule detection [J].
Lou, SL ;
Chang, CL ;
Lin, KP ;
Chen, TS .
MEDICAL IMAGING 1999: IMAGE PROCESSING, PTS 1 AND 2, 1999, 3661 :1544-1552
[9]   Anti-geometric diffusion for adaptive thresholding and fast segmentation [J].
Manay, S ;
Yezzi, A .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 2003, 12 (11) :1310-1323
[10]  
MATSUMOTO S, 2006, INT J CARS, V1, P345