High-throughput microwave-digestion procedures to monitor neurotoxic elements in body fluids by means of inductively coupled plasma mass spectrometry

被引:42
作者
Bocca, B
Alimonti, A
Forte, G
Petrucci, F
Pirola, C
Senofonte, O
Violante, N
机构
[1] Ist Super Sanita, I-00161 Rome, Italy
[2] Milestone Srl, I-24010 Bergamo, Italy
关键词
neuro-toxic elements; sample pretreatment; microwave digestion; ICP-MS; biological fluids; urine; serum; blood;
D O I
10.1007/s00216-003-2029-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Microwave (MW) digestion procedures with high sample throughput (simultaneous digestion of 36 or 80 samples) and procedural simplicity (disposable plastic tubes, or re-usable liners with screw-cap) were investigated for their efficiency in routine analyses of biological samples. Different digestion vessel materials were tested for metal leaching/adsorption and thermal resistance: quartz, glass, polyethylene (PE) and polystyrene (PS). For the instrumental quantification of Al, Bi, Cd, Co, Cr, Hg, Mn, Mo, Ni, Pb, Sb, and Tl at ultra-trace levels in urine, serum, and whole blood, sector field inductively coupled plasma mass spectrometry (SF-ICP-MS) was used. The different pretreatment conditions and vessels were evaluated in terms of contamination risk, effective power of detection, accuracy, and precision. Results of analyses of serum, urine and whole blood certified reference materials (CRMs) were fully satisfactory for almost all the analytes. In the case of Hg, Mo, and Tl in serum digested in plastic containers the results were just below the lower limit of uncertainty of the certified range. On the basis of the present data the following MW procedures can be suggested: 1.for urine, digestion with nitric acid at atmospheric pressure in plastic vials; 2.for serum, digestion with nitric acid at atmospheric pressure in glass vessels; and 3.for whole blood, digestion under pressure in quartz tubes. Because of the levels of the procedural blanks, Bi was not measurable at the concentrations expected in human fluids, and Al was accurately detectable in whole blood only.
引用
收藏
页码:65 / 70
页数:6
相关论文
共 22 条
[1]   DETERMINATION OF CHROMIUM AND NICKEL IN HUMAN BLOOD BY MEANS OF INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
ALIMONTI, A ;
PETRUCCI, F ;
SANTUCCI, B ;
CRISTAUDO, A ;
CAROLI, S .
ANALYTICA CHIMICA ACTA, 1995, 306 (01) :35-41
[2]   New horizons in human biomonitoring of environmentally and occupationally relevant metals-sector-field ICP-MS versus electrothermal AAS [J].
Begerow, J ;
Turfeld, M ;
Dunemann, L .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (04) :347-352
[3]   Molecular mechanisms of lead neurotoxicity [J].
Bressler, J ;
Kim, K ;
Chakraborti, T ;
Goldstein, G .
NEUROCHEMICAL RESEARCH, 1999, 24 (04) :595-600
[4]   THE ASSESSMENT OF REFERENCE VALUES FOR ELEMENTS IN HUMAN BIOLOGICAL TISSUES AND FLUIDS - A SYSTEMATIC REVIEW [J].
CAROLI, S ;
ALIMONTI, A ;
CONI, E ;
PETRUCCI, F ;
SENOFONTE, O ;
VIOLANTE, N .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1994, 24 (5-6) :363-398
[5]   ALZHEIMERS-DISEASE AND ENVIRONMENTAL ALUMINUM [J].
DOLL, R .
AGE AND AGEING, 1993, 22 (02) :138-153
[6]  
Gorell JM, 1999, NEUROTOXICOLOGY, V20, P239
[7]   Reevaluation of the trace element content in Reference Man [J].
Iyengar, GV .
RADIATION PHYSICS AND CHEMISTRY, 1998, 51 (4-6) :545-560
[8]   A PARTIALLY MECHANIZED SYSTEM FOR THE COMBUSTION OF ORGANIC-SAMPLES IN A STREAM OF OXYGEN WITH QUANTITATIVE RECOVERY OF THE TRACE-ELEMENTS [J].
KNAPP, G ;
RAPTIS, SE ;
KAISER, G ;
TOLG, G ;
SCHRAMEL, P ;
SCHREIBER, B .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1981, 308 (02) :97-103
[9]   Influence of sample pre-treatment on the determination of trace elements in urine by quadrupole and magnetic sector field inductively coupled plasma mass spectrometry [J].
Krachler, M ;
Alimonti, A ;
Petrucci, F ;
Forastiere, F ;
Caroli, S .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (08) :701-705
[10]   Use of ultrasonic nebulizer with desolvator membrane for the determination of titanium and zirconium in human serum by means of inductively coupled plasma-mass spectroscopy [J].
Kunze, J ;
Koelling, S ;
Reich, M ;
Wimmer, MA .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 366 (02) :165-166