Treating severe cardiogenic shock by large counterpulsation volumes

被引:15
作者
Stamatelopoulos, SF [1 ]
Nanas, JN [1 ]
Saridakis, NS [1 ]
Zakopoulos, NA [1 ]
Lyropoulos, S [1 ]
Makrakis, G [1 ]
Liberidis, A [1 ]
Moulopoulos, SD [1 ]
机构
[1] UNIV ATHENS,SCH MED,DEPT CLIN THERAPEUT,GR-11527 ATHENS,GREECE
关键词
D O I
10.1016/0003-4975(96)00396-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Intraaortic balloon pumping is known to be ineffective in severe cardiogenic shock. The efficacy of balloon volumes larger than those commonly used is examined. Methods. In 18 dogs with severe experimental cardiogenic shock (systolic aortic pressure <60 mm Hg, aortic flow <45 mL . min(-1) . kg(-1)) the effect of three intraaortic balloon volumes (15, 30, and 45 mL) and a 60-mL paraaortic pump was examined. Results. The 45-mL balloon covering the full length of the aorta induced the highest (+12.4 +/- 2.2 mL . min(-1) . kg(-1)); mean +/- standard error of the mean) and the 15-mL balloon the lowest increase in aortic flow (F = 14.6, p < 0.0001). Only the 45-mL balloon increased < 0.05) urine output and renal artery flow. The 60-mL paraaortic pump induced the highest (F = 10.72, p < 0.002) increase (+36.6 +/- 6.5 mL . min(-1) . kg(-1)) in aortic flow compared to the three balloons. An 80- to 100-mL paraaortic pump maintained the life of 3 patients in severe cardiogenic shock for 4 hours, 8 days, and 54 days, whereas a 40-mL conventional balloon was completely ineffective. Conclusions. Experimental and clinical data indicate that the effectiveness of intraaortic balloon pumping in severe cardiogenic shock may be improved by increasing the volume of the balloon (ie, until it fully occupies the aorta).
引用
收藏
页码:1110 / 1117
页数:8
相关论文
共 12 条
[1]   DIASTOLIC AUGMENTATION BY INTRA-AORTIC BALLOON - CIRCULATORY HEMODYNAMICS AND TREATMENT OF SEVERE ACUTE LEFT VENTRICULAR FAILURE IN DOGS [J].
BROWN, BG ;
GOLDFARB, D ;
TOPAZ, SR ;
GOTT, VL .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1967, 53 (06) :789-&
[2]  
CHRISTOFERSEN EB, 1972, SCAND J CLIN LAB S1, V29, P9
[3]   INTRAAORTIC BALLOON PUMPING IN EXPERIMENTAL ANIMAL - EFFECTS AND PROBLEMS [J].
FEOLA, M ;
ADACHI, M ;
AKERS, WW ;
ROSS, JN ;
WIETING, DW ;
KENNEDY, JH .
AMERICAN JOURNAL OF CARDIOLOGY, 1971, 27 (02) :129-&
[4]  
KANTROWITZ A, 1995, ASSISTED CIRCULATION, V4, P12
[5]  
MOULOPOULOS S, 1995, ASSISTED CIRCULATION, V4, P36
[6]  
MOULOPOULOS S, 1976, 7 EUR C CARD, V1, P708
[7]   DIASTOLIC BALLOON PUMPING (WITH CARBON DIOXIDE) IN AORTA-A MECHANICAL ASSISTANCE TO FAILING CIRCULATION [J].
MOULOPOULOS, SD ;
TOPAZ, S ;
KOLFF, WJ .
AMERICAN HEART JOURNAL, 1962, 63 (05) :669-&
[8]   THE LIMITS OF COUNTERPULSATION [J].
MOULOPOULOS, SD .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1993, 16 (12) :803-805
[9]  
NANAS J, 1990, ASAIO T, V36, P505
[10]  
Nanas J N, 1988, ASAIO Trans, V34, P229