Understanding capacitively coupled contactless conductivity detection in capillary and microchip electrophoresis. Part 1. Fundamentals

被引:228
作者
Brito-Neto, JGA
da Silva, JAF
Blanes, L
do Lago, CL
机构
[1] Univ Sao Paulo, Inst Quim, Dept Quim Fundamental, BR-05508900 Sao Paulo, Brazil
[2] Univ Estadual Campinas, Inst Quim, Dept Quim Analit, BR-13083970 Campinas, SP, Brazil
关键词
capillary electrophoresis; contactless conductivity detection; simulation; (CD)-D-4; CCD;
D O I
10.1002/elan.200503237
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Capacitively coupled contactless conductivity detection ((CD)-D-4) is presented in a progressively detailed approach. Through different levels of theoretical and practical complexity, several aspects related to this kind of detection are addressed, which should be helpful to understand the results as well as to design a detector or plan experiments. Simulations and experimental results suggest that sensitivity depends on: 1) the electrolyte co-ion and counter-ion; 2) cell geometry and its positioning; 3) operating frequency. Undesirable stray capacitance formed due to the close placement of the electrodes is of great importance to the optimization of the operating frequency and must be minimized.
引用
收藏
页码:1198 / 1206
页数:9
相关论文
共 46 条
  • [1] SIMULTANEOUS CONDUCTIVITY AND PERMITTIVITY DETECTOR WITH A SINGLE CELL FOR LIQUID-CHROMATOGRAPHY
    ALDER, JF
    FIELDEN, PR
    CLARK, AJ
    [J]. ANALYTICAL CHEMISTRY, 1984, 56 (06) : 985 - 988
  • [2] BURKHALTER TS, 1964, HIGH FREQUENCY CONDU, P215
  • [3] Determination of mono- and disaccharides by capillary electrophoresis with contactless conductivity detection
    Carvalho, AZ
    da Silva, JAF
    do Lago, CL
    [J]. ELECTROPHORESIS, 2003, 24 (12-13) : 2138 - 2143
  • [4] da Silva JAF, 2002, J CHROMATOGR A, V942, P249
  • [5] da Silva JAF, 1998, ANAL CHEM, V70, P4339
  • [6] da Silva JAF, 2000, ELECTROPHORESIS, V21, P1405, DOI 10.1002/(SICI)1522-2683(20000401)21:7<1405::AID-ELPS1405>3.0.CO
  • [7] 2-O
  • [8] Improved separation of IA and IIA metal cations in matrices with high sodium concentration by capillary electrophoresis with contactless conductometric detection
    da Silva, JAF
    Ricelli, NL
    Carvalho, AZ
    do Lago, CL
    [J]. JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2003, 14 (02) : 265 - 268
  • [9] Extending the lifetime of the running electrolyte in capillary electrophoresis by using additional compartments for external electrolysis
    de Jesus, DP
    Brito-Neto, JGA
    Richter, EM
    Angnes, L
    Gutz, IGR
    do Lago, CL
    [J]. ANALYTICAL CHEMISTRY, 2005, 77 (02) : 607 - 614
  • [10] Determination of boron by using a quartz crystal resonator coated with N-methyl-D-glucamine-modified poly(epichlorohydrin)
    de Jesus, DP
    Neves, CA
    do Lago, CL
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (14) : 3274 - 3280