The effect of combined arterial hemodynamics on saphenous venous endothelial nitric oxide production

被引:37
作者
Casey, PJ [1 ]
Dattilo, JB [1 ]
Dai, GH [1 ]
Albert, JA [1 ]
Tsukurov, OI [1 ]
Orkin, RW [1 ]
Gertler, JP [1 ]
Abbott, WM [1 ]
机构
[1] Massachusetts Gen Hosp, Div Vasc Surg, Boston, MA 02114 USA
关键词
D O I
10.1067/mva.2001.115571
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction: Evidence exists that an ideal bypass conduit should have a functional endothelial cell surface combined with mechanical properties similar to those of native arteries. We hypothesized that the effect of combined arterial levels of pulsatile shear stress, flow, and cyclic strain would enhance saphenous venous endothelial cell nitric oxide (NO) production, and that variations in these "ideal" conditions could impair this function. We studied NO production as a measure of endothelial function in response to different hemodynamic conditions. Methods: Human adult saphenous venous endothelial cells were cultured in 10-cm silicone tubes, similar in diameter (5 mm) and compliance (6%) to a medium-caliber peripheral artery (eg, popliteal). Tube cultures were exposed to arterial conditions: a combined pressure (120/80 mm/Hg; mean, 100 mm/Hg), flow (mean, 115 mL/min) and cyclic strain (2%), with a resultant pulsatile shear stress of 4.8 to 9.4 dyne/cm(2) (mean, 7.1). Identical tube cultures were used to study variations in these conditions. Modifications of the system included a noncompliant system, a model with non-pulsatile flow, and a final group exposed to pulsatile pressure with no flow NO levels were measured with, fluorometric nitrite assay of conditioned media collected at 0, 0.25, 0.5, 1, 2, and 4 hours. Experimental groups were compared with cells exposed to nonpulsatile, nonpressurized low flow (shear stress 0.1 dyne/cm(2)) and static cultures. Results: Ah experimental groups had greater rates of NO production than cells under static conditions (P < .05). Cells exposed to ideal conditions produced the greatest levels of NO. Independent decreases in compliance, flow, and pulsatility resulted in significantly lower rates of NO production than those in the group with these conditions intact (vs noncompliant P < .05, vs nonflow P < .05, and vs nonpulsatile P < .05). Conclusions: Our results show that in the absence of physiologically normal pulsatility, cyclic strain, and Volume flow endothelial NO production does not reach the levels seen under ideal conditions. Pulsatile flow and compliance (producing flow with cyclic stretch) play a key role in NO production by vascular endothelium in a three-dimensional hemodynamically active model. This correlates biologically with clinical experience linking graft inflow and runoff and the mechanical properties of the conduit to long-term patency.
引用
收藏
页码:1199 / 1204
页数:6
相关论文
共 29 条
[1]   EFFECT OF COMPLIANCE MISMATCH ON VASCULAR GRAFT PATENCY [J].
ABBOTT, WM ;
MEGERMAN, J ;
HASSON, JE ;
LITALIEN, G ;
WARNOCK, DF .
JOURNAL OF VASCULAR SURGERY, 1987, 5 (02) :376-382
[2]  
AWOLESI MA, 1994, SURGERY, V116, P439
[3]  
BAIRD RN, 1977, AM J PHYSIOL, V233, P568
[4]   A COMPLIANT TUBULAR DEVICE TO STUDY THE INFLUENCES OF WALL STRAIN AND FLUID SHEAR-STRESS ON CELLS OF THE VASCULAR WALL [J].
BENBRAHIM, A ;
LITALIEN, GJ ;
MILINAZZO, BB ;
WARNOCK, DF ;
DHARA, S ;
GERTLER, JP ;
ORKIN, RW ;
ABBOTT, WM .
JOURNAL OF VASCULAR SURGERY, 1994, 20 (02) :184-194
[5]   Characteristics of vascular wall cells subjected to dynamic cyclic strain and fluid shear conditions in vitro [J].
Benbrahim, A ;
LItalien, GJ ;
Kwolek, CJ ;
Petersen, MJ ;
Milinazzo, B ;
Gertler, JP ;
Abbott, WM ;
Orkin, RW .
JOURNAL OF SURGICAL RESEARCH, 1996, 65 (02) :119-127
[6]   Surgical implications of vascular endothelial physiology [J].
Cain, BS ;
Meldrum, DR ;
Selzman, CH ;
Cleveland, JC ;
Meng, XZ ;
Sheridan, BC ;
Banerjee, A ;
Harken, AH .
SURGERY, 1997, 122 (03) :516-526
[7]   CHRONIC CHANGES IN BLOOD-FLOW ALTER ENDOTHELIUM-DEPENDENT RESPONSES IN AUTOGENOUS VEIN GRAFTS IN DOGS [J].
CAMBRIA, RA ;
LOWELL, RC ;
GLOVICZKI, P ;
MILLER, VM .
JOURNAL OF VASCULAR SURGERY, 1994, 20 (05) :765-773
[8]   THE EVOLUTION OF MORPHOLOGICAL AND BIOMECHANICAL CHANGES IN REVERSED AND INSITU VEIN GRAFTS [J].
CAMBRIA, RP ;
MEGERMAN, J ;
BREWSTER, DC ;
HASSON, J ;
WARNOCK, DF ;
ABBOTT, WM .
ANNALS OF SURGERY, 1987, 205 (02) :167-174
[9]  
CAMBRIA RP, 1989, VASCULAR SURG, P425
[10]  
CAMPEAU L, 1983, CIRCULATION, V68, P1