Real-time, monitor for hemodynamic beat-to-beat parameters and power spectra analysis of the biosignals

被引:41
作者
Fortin, J [1 ]
Habenbacher, W [1 ]
Gruellenberger, R [1 ]
Wach, P [1 ]
Skrabal, F [1 ]
机构
[1] Graz Univ Technol, Inst Biomed Engn, Dept Biophys, A-8010 Graz, Austria
来源
PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND | 1998年 / 20卷
关键词
D O I
10.1109/IEMBS.1998.745917
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In this work a system for the online analysis of all relevant hemodynamic parameters is introduced. The parameters are heart rate, systolic, diastolic and mean blood pressure, stroke volume, cardiac output, total peripheral resistance, inotropic state, oxygen saturation, several time intervals, the power of the high and low frequency band of hemodynamic time series and baroreceptor reflex sensitivity. The system consists of a patient biosignal electronic system (PBES) which is a self calibrating, non-invasive instrument for EGG, impedance cardiography ICG, continuous blood pressure and pulse oximetry. The data acquisition (DAQ) system is a personal computer with a C-based software for DAQ and virtual instrumentation. This software is controlling the calibration routines of the PEES, detecting the beat-to-beat hemodynamic parameters, computing the sliding power spectra and calculating the baroreceptor sensitivity. The data are visualised in real-time on the screen and finally an automatic report of the investigation is printed. A new algorithm for online QRS-detection and a new rejection method for the RLS-algorithm are included.
引用
收藏
页码:360 / 363
页数:4
相关论文
共 11 条
[1]  
[Anonymous], 1973, 10 INT C MED BIOL EN
[2]   Continuous monitoring of the sympatho-vagal balance through spectral analysis [J].
Bianchi, AM ;
Mainardi, LT ;
Meloni, C ;
Chierchia, S ;
Cerutti, S .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1997, 16 (05) :64-73
[3]   NONINVASIVE VS INVASIVE BEAT-TO-BEAT MONITORING OF BLOOD-PRESSURE [J].
GABRIEL, A ;
LINDBLAD, LE ;
ANGLERYD, C .
CLINICAL PHYSIOLOGY, 1992, 12 (02) :229-235
[4]  
GRATZE G, 1998, IN PRESS COMPUTERS B
[5]  
KUBICEK WG, 1966, AEROSPACE MED, V37, P1208
[6]   DETECTION OF ECG CHARACTERISTIC POINTS USING WAVELET TRANSFORMS [J].
LI, CW ;
ZHENG, CX ;
TAI, CF .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1995, 42 (01) :21-28
[7]  
PAN J, 1986, IEEE T BIOMED ENG, V33, P1157
[8]  
PARATI G, 1992, BLOOD PRESSURE HEART, P123, DOI DOI 10.1097/HJH.0B013E3283588189
[9]   Adaptive autoregressive modeling used for single-trial EEG classification [J].
Schlogl, A ;
Flotzinger, D ;
Pfurtscheller, G .
BIOMEDIZINISCHE TECHNIK, 1997, 42 (06) :162-167
[10]   AN ADVANCED SIGNAL-PROCESSING TECHNIQUE FOR IMPEDANCE CARDIOGRAPHY [J].
WANG, XA ;
SUN, HH ;
VANDEWATER, JM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1995, 42 (02) :224-230