Bone ingrowth in macroporous Bonelike® for orthopaedic applications

被引:26
作者
Gutierres, M. [2 ]
Lopes, M. A. [1 ,3 ]
Hussain, N. Sooraj [1 ,3 ]
Lemos, A. F. [4 ]
Ferreira, J. M. F. [4 ]
Afonso, A. [5 ]
Cabral, A. T. [2 ]
Almeida, L. [2 ]
Santos, J. D. [1 ,3 ]
机构
[1] Univ Porto, Fac Engn, FEUP, P-4200465 Oporto, Portugal
[2] Univ Porto, Hosp Sao Joao, Fac Med, FMUP, P-4200 Oporto, Portugal
[3] Inst Biomed Engn INEB, Lab Biomat, P-4150180 Oporto, Portugal
[4] Univ Aveiro, UIMC, Dep De Eng Ceramica Vidro, P-3800 Aveiro, Portugal
[5] Univ Porto, Fac Med Dent, FMDUP, P-4200393 Oporto, Portugal
关键词
Bonelike (R); porous materials; bone graft; orthopaedic;
D O I
10.1016/j.actbio.2007.06.009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this study was to evaluate the biological behaviour of porous scaffold structures of Bonelike(R) which is suitable for either direct clinical use or tissue engineering applications. Porous cylindrical specimens 8 x 10 mm were implanted in the lateral aspect of the tibia of 13 patients (mean age 54 years), during osteotomy surgery for the treatment of medial compartment osteoarthritis of the knee. Implanted cylinders were retrieved at the same time as the removal of the blade plates at 3, 6, 9 and 12 months. Scanning electron microscopy and histological evaluations were performed to observe the biological responses of human bone tissue to porous Bonelike(R). The penetration depth was determined for all implantation periods, and after 6 months it was already possible to see new bone in the centre of the implanted cylinders, which gives 100% of penetration depth for all implantations periods except for 3 months when bone could only be seen in the peripherical region. Regarding the percentage of the area covered by new bone calculated from two-dimensional histological sections, values of 53 +/- 15, 76 +/- 12 and 88 +/- 9% were achieved for 6, 9 and 12 months, respectively. Due to its structural features porous Bonelikee permitted effective vascularization and bone ingrowth, and therefore was fully osteointegrated as shown in the histological surveys. A slow biomaterial degradation with implantation time is envisaged since the material has displayed surface degradation. Bonelike(R) scaffolds show potential for complete ingrowth of osseous tissue and restoration of vascularization throughout the defected site. (C) 2007 Published by Elsevier Ltd. on behalf of Acta Materialia Inc.
引用
收藏
页码:370 / 377
页数:8
相关论文
共 55 条
[1]  
AKAMATSU Y, 1997, CLIN ORTHOP RELAT R, V334, P207
[2]  
Ayers RA, 1999, J BIOMED MATER RES, V47, P54, DOI 10.1002/(SICI)1097-4636(199910)47:1<54::AID-JBM7>3.3.CO
[3]  
2-G
[4]   Natural bioceramics: from coral to bone and beyond [J].
Ben-Nissan, B .
CURRENT OPINION IN SOLID STATE & MATERIALS SCIENCE, 2003, 7 (4-5) :283-288
[5]   PROXIMAL TIBIAL OSTEOTOMY - A CRITICAL LONG-TERM STUDY OF 87 CASES [J].
COVENTRY, MB ;
ILSTRUP, DM ;
WALLRICHS, SL .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (02) :196-201
[6]   UPPER TIBIAL OSTEOTOMY FOR OSTEO-ARTHRITIS [J].
COVENTRY, MB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (07) :1136-1140
[7]  
COVENTRY MB, 1979, ORTHOP CLIN N AM, V10, P191
[9]   Production of porous biomaterials based on glass-reinforced hydroxyapatite composites [J].
da Silva, MHP ;
Lemos, AF ;
Ferreira, JMF ;
Lopes, MA ;
Santos, JD .
ADVANCED MATERIALS FORUM I, 2002, 230-2 :483-486
[10]   Porous glass reinforced hydroxyapatite materials produced with different organic additives [J].
da Silva, MHP ;
Lemos, AF ;
Gibson, IR ;
Ferreira, JMF ;
Santos, JD .
JOURNAL OF NON-CRYSTALLINE SOLIDS, 2002, 304 (1-3) :286-292