Resolution improvements in in vivo 1H NMR spectra with increased magnetic field strength

被引:158
作者
Gruetter, R [1 ]
Weisdorf, SA
Rajanayagan, V
Terpstra, M
Merkle, H
Truwit, CL
Garwood, M
Nyberg, SL
Ugurbil, K
机构
[1] Univ Minnesota, Dept Radiol, Minneapolis, MN 55112 USA
[2] Univ Minnesota, Dept Pediat, Minneapolis, MN 55112 USA
[3] Mayo Clin & Mayo Fdn, Dept Surg, Rochester, MN 55905 USA
关键词
brain; magnetic field; in vivo; H-1; NMR; resolution;
D O I
10.1006/jmre.1998.1542
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The measurement of cerebral metabolites using highly homologous localization techniques and similar shimming methods was performed in the human brain at 1.5 and 4 T as well as in the dog and rat brain at 9.4 T. In rat brain, improved resolution was achieved by shimming all first- and second-order shim coils using a fully adiabatic FASTMAP sequence. The spectra showed a clear improvement in spectral resolution for all metabolite resonances with increased field strength. Changes in cerebral glutamine content were clearly observed at 4 T compared to 1.5 T in patients with hepatic encephalopathy. At 9.4 T, glutamine H4 at 2.46 ppm was fully resolved from glutamate H4 at 2.37 ppm, as was the potential resonance from gamma-amino-butyric acid at 2.30 ppm and N-acetyl-aspartyl-glutamate at 2.05 ppm. Singlet linewidths were found to be as low as 6 Hz (0.015 ppm) at 9.4 T, indicating a substantial decrease in ppm linewidth with field strength. Furthermore, the methylene peak of creatine was partially resolved from phosphocreatine, indicating a close to 1:1 relationship in gray matter. We conclude that increasing the magnetic field strength increases spectral resolution also for H-1 NMR, which can lead to more than linear sensitivity gains. (C) 1998 Academic Press.
引用
收藏
页码:260 / 264
页数:5
相关论文
共 40 条
[1]   QUANTITATIVE PROTON SPECTROSCOPY OF CANINE BRAIN - IN-VIVO AND IN-VITRO CORRELATIONS [J].
BARKER, PB ;
BREITER, SN ;
SOHER, BJ ;
CHATHAM, JC ;
FORDER, JR ;
SAMPHILIPO, MA ;
MAGEE, CA ;
ANDERSON, JH .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (02) :157-163
[2]   ANALYSIS OF GLYCOGEN-STORAGE-DISEASE BY INVIVO C-13 NMR - COMPARISON OF NORMAL VOLUNTEERS WITH A PATIENT [J].
BECKMANN, N ;
SEELIG, J ;
WICK, H .
MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (01) :150-160
[3]   ANALYSIS OF MACROMOLECULE RESONANCES IN H-1-NMR SPECTRA OF HUMAN BRAIN [J].
BEHAR, KL ;
ROTHMAN, DL ;
SPENCER, DD ;
PETROFF, OAC .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (03) :294-302
[4]   Dynamic shim updating: A new approach towards optimized whole brain shimming [J].
Blamire, AM ;
Rothman, DL ;
Nixon, T .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (01) :159-165
[5]   COMPARISON OF P-31 MRS AND H-1 MRI AT 1.5-T AND 2.0-T [J].
BOSKA, MD ;
HUBESCH, B ;
MEYERHOFF, DJ ;
TWIEG, DB ;
KARCZMAR, GS ;
MATSON, GB ;
WEINER, MW .
MAGNETIC RESONANCE IN MEDICINE, 1990, 13 (02) :228-238
[6]   Quantitative neuropathology by high resolution magic angle spinning proton magnetic resonance spectroscopy [J].
Cheng, LL ;
Ma, MJ ;
Becerra, L ;
Ptak, T ;
Tracey, I ;
Lackner, A ;
Gonzalez, RG .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1997, 94 (12) :6408-6413
[7]   A REDUCED POWER SELECTIVE ADIABATIC SPIN-ECHO PULSE SEQUENCE [J].
CONOLLY, S ;
GLOVER, G ;
NISHIMURA, D ;
MACOVSKI, A .
MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (01) :28-38
[8]   B-1-insensitive, single-shot localization and water suppression [J].
deGraaf, RA ;
Luo, Y ;
Garwood, M ;
Nicolay, K .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1996, 113 (01) :35-45
[9]   ON THE USE OF 2-DIMENSIONAL-J NMR MEASUREMENTS FOR IN-VIVO PROTON MRS - MEASUREMENT OF HOMONUCLEAR DECOUPLED SPECTRA WITHOUT THE NEED FOR SHORT ECHO TIMES [J].
DREHER, W ;
LEIBFRITZ, D .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (03) :331-337
[10]   Observation of resolved glucose signals in H-1 NMR spectra of the human brain at 4 Tesla [J].
Gruetter, R ;
Garwood, M ;
Ugurbil, K ;
Seaquist, ER .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (01) :1-6