Transfer number in fine bubble diffused aeration systems

被引:13
作者
Capela, S
Roustan, M
Héduit, A
机构
[1] Cemagref, Unite Rech Qualite & Fonctionnement Hydrol Syst A, F-92163 Antony, France
[2] Inst Natl Sci Appl, Lab Ingn Procedes Environm, F-31077 Toulouse 4, France
关键词
clean water tests; fine bubble aeration; oxygen transfer;
D O I
10.2166/wst.2001.0677
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
On the basis of full-scale data from 58 clean water tests performed in 26 activated sludge tanks equipped with fine bubble diffusers and of a theoretical approach, it can be stated that fine bubble aeration systems with total floor coverage arrangement provide higher kLa values and the lowest spiral liquid circulation. An efficiency criterion for oxygen transfer (NT) was defined on the basis of the dimensional analysis. The transfer number NT allows us to take account of the impact of vertical liquid circulation movements on oxygen transfer. The values of NT calculated from the results of full scale nonsteady-state clean water tests vary from 5.3x10(-5) to 9.1x10(-5) and are directly dependent upon the arrangement of air diffusers. It has been shown that the highest transfer numbers corresponded to the total floor coverage arrangement and the average calculated N-T values is 7.7x10(-5), independently of the diffuser density and of the gas velocity, over the ranges studied. The lowest transfer numbers are obtained when the diffusers are located in separate grids, and the transfer number is reduced with increasing air flow rate.
引用
收藏
页码:145 / 152
页数:8
相关论文
共 21 条
[1]  
[Anonymous], THESIS INSA TOULOUSE
[2]  
*ASCE, 1994, MAN PRACT
[3]  
*ASCE, 1992, ASCE STAND MEAS OX T
[4]  
*ATV, 1996, MESS SAUERST BEL BEL
[5]  
DASILVADERONZIE.G, 1994, THESIS U L PASTEUR S
[6]   Optimization of oxygen transfer in clean water by fine bubble diffused air system and separate mixing in aeration ditches [J].
Deronzier, G ;
Duchene, P ;
Heduit, A .
WATER SCIENCE AND TECHNOLOGY, 1998, 38 (03) :35-42
[7]  
DUCHENE P, 1995, GESTION MILIEUX AQUA, V9
[8]   Effects of air diffuser arrangement on hydrodynamics and oxygen transfer in activated sludge aeration tanks [J].
Fujie, K ;
Kasakura, T ;
Tsuchiya, K ;
Tomita, Y .
ENVIRONMENTAL TECHNOLOGY, 1997, 18 (06) :663-668
[9]  
GILLOT S, 1998, IN PRESS WAT RES
[10]   TESTS ON AERATORS - CONCLUSIONS DRAWN FROM 500 CLEAN WATER TESTS CONDUCTED IN 200 DIFFERENT SEWAGE-TREATMENT PLANTS .1. TEST PROCEDURE [J].
HEDUIT, A ;
RACAULT, Y .
WATER RESEARCH, 1983, 17 (01) :97-103