How do lateral hinge and distraction affect three-dimensional rotation in open wedge high tibial osteotomy?

被引:5
作者
Chang, Shih-Sheng [1 ,2 ,3 ,4 ]
Lin, Shang-Chih [1 ]
Chan, Yi-Sheng [2 ,3 ,4 ]
Wu, Chen-Te [5 ]
Hsu, Kuo-Yao [2 ,3 ,4 ]
Chen, Chun-Ming [1 ]
Hsu, Chi-Pin [1 ,6 ]
机构
[1] Natl Taiwan Univ Sci & Technol, Grad Inst Biomed Engn, 43,Sec 4,Keelung Rd, Taipei 106, Taiwan
[2] Chang Gung Mem Hosp, Dept Orthoped Surg, Div Sports Med, Taoyuan, Taiwan
[3] Chang Gung Mem Hosp, Musculoskeletal Res Ctr, Taoyuan, Taiwan
[4] Chang Gung Univ, Coll Med, Taoyuan, Taiwan
[5] Chang Gung Mem Hosp, Dept Med Imaging & Intervent Radiol, Linkou, Taiwan
[6] Natl Taiwan Univ Sci & Technol, High Speed 3D Printing Res Ctr, Taipei, Taiwan
关键词
SLOPE;
D O I
10.1016/j.jos.2020.10.006
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Background: Open-wedge high tibial osteotomy (OWHTO) has extensively been used for the correction of medial knee osteoarthritis. The proximal tibia is osteotomized and distracted to enable the rotation of tibial fragments around the lateral hinge. Both, wedge inclination on the medial side and saw progression near the lateral cortex determine the hinge orientation. This study focused on the interaction between hinge orientation and distraction sites on the coronal, sagittal, and horizontal planes of the distracted plateau. Methods: Three parameters of wedge inclination, saw progression, and distraction site (i.e., posterior, middle, and anterior) were systematically varied. Using a three-dimensional (3D)-printing technique, the osteotomized tibiae were manufactured as the specimens for the in vitro experiments. In total, 27 variations (3 x 3 x 3) were tested. After distraction, the specimens were scanned by computed tomography and spatially registered with the original tibia to compare the 3D angles of the distracted plateaus. Results: Coronal rotation is the main purpose of OWHTO; therefore, all the values of the coronal angles were positive and significantly higher than the other two. The sagittal and horizontal angles had relatively similar values. Distraction in the middle site seems to have the least impact on sagittal rotation. Large angles of hinge orientation show the superior ability in adjusting the sagittal rotation than small angles. However, the larger the horizontal angles the greater the wedge inclination. Conclusions: The wedge inclination, saw progression, and distraction site constitute a complex mechanism that affects 3D rotations of the distracted plateau. The coronal angles are sensitive to hinge orientation and distraction site. The intraoperative planning of manipulating hinge orientation is an effective method to adjust sagittal rotation. A large angle of wedge inclination is an indicator of horizontal rotation, and it should be carefully mitigated to reduce the risk of cracking in the lateral hinge. (c) 2020 Published by Elsevier B.V. on behalf of The Japanese Orthopaedic Association.
引用
收藏
页码:1056 / 1063
页数:8
相关论文
共 30 条
[1]
Should sagittal osteotomy line be parallel to tibial posterior slope in high tibial osteotomy? [J].
Akamatsu, Y. ;
Kobayashi, H. ;
Tsuji, M. ;
Nejima, S. ;
Kumagai, K. ;
Saito, T. .
BMC MUSCULOSKELETAL DISORDERS, 2018, 19
[2]
Tibial Slope and Its Effect on Force in Anterior Cruciate Ligament Grafts: Anterior Cruciate Ligament Force Increases Linearly as Posterior Tibial Slope Increases [J].
Bernhardson, Andrew S. ;
Aman, Zachary S. ;
Dornan, Grant J. ;
Kemler, Bryson R. ;
Storaci, Hunter W. ;
Brady, Alex W. ;
Nakama, Gilberto Y. ;
LaPrade, Robert F. .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2019, 47 (02) :296-302
[3]
Dragosloveanu Serban, 2014, Maedica (Bucur), V9, P173
[4]
Incidence and Predictors of Lateral Hinge Fractures Following Medial Opening-Wedge High Tibial Osteotomy Using Locking Plate System: Better Performance of Computed Tomography Scans [J].
Han, Seung-Beom ;
Choi, Jae-Hyuk ;
Mahajan, Atul ;
Shin, Young-Soo .
JOURNAL OF ARTHROPLASTY, 2019, 34 (05) :846-851
[5]
Satisfactory functional and radiological outcomes can be expected in young patients under 45 years old after open wedge high tibial osteotomy in a long-term follow-up [J].
Hantes, Michael E. ;
Natsaridis, Prodromos ;
Koutalos, Antonios A. ;
Ono, Yohei ;
Doxariotis, Nikolaos ;
Malizos, Konstantinos N. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2018, 26 (11) :3199-3205
[6]
Open wedge tibial osteotomy: combined coronal and sagittal correction [J].
Hernigou, P .
KNEE, 2002, 9 (01) :15-20
[7]
Analysis of the effects of high tibial osteotomy on tibial rotation [J].
Hinterwimmer, Stefan ;
Feucht, Matthias J. ;
Paul, Jochen ;
Kirchhoff, Chlodwig ;
Sauerschnig, Martin ;
Imhoff, Andreas B. ;
Beitzel, Knut .
INTERNATIONAL ORTHOPAEDICS, 2016, 40 (09) :1849-1854
[8]
Hybrid closed wedge high tibial osteotomy improves patellofemoral joint congruity compared with open wedge high tibial osteotomy [J].
Ishimatsu, Tetsuro ;
Takeuchi, Ryohei ;
Ishikawa, Hiroyuki ;
Yamaguchi, Yuichiro ;
Maeyama, Akira ;
Osawa, Katsunari ;
Jung, Woon-Hwa .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2019, 27 (04) :1299-1309
[9]
Factors influencing posterior tibial slope and tibial rotation in opening wedge high tibial osteotomy [J].
Jacobi, Matthias ;
Villa, Vincent ;
Reischl, Nikolaus ;
Demey, Guillaume ;
Goy, Damien ;
Neyret, Philippe ;
Gautier, Emanuel ;
Magnussen, Robert A. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (09) :2762-2768
[10]
Temperatures and chemical potentials at kinetic freeze-out in relativistic heavy ion collisions from coarse grained transport simulations [J].
Inghirami, Gabriele ;
Hillmann, Paula ;
Tomasik, Boris ;
Bleicher, Marcus .
JOURNAL OF PHYSICS G-NUCLEAR AND PARTICLE PHYSICS, 2020, 28 (12) :3849-3857