Microwave-assisted extraction of OCPs, PCBs and PAHs concentrated by semi-permeable membrane devices (SPMDs)

被引:44
作者
Yusà, V [1 ]
Pastor, A [1 ]
de la Guardia, M [1 ]
机构
[1] Univ Valencia, Dept Analyt Chem, E-46100 Valencia, Spain
关键词
semi-permeable membrane device; SPMD; microwave-assisted extraction; MAE; organochlorine pesticides; polychlorinated biphenyls; polycyclic aromatic hydrocarbons;
D O I
10.1016/j.aca.2005.03.010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microwave-assisted extraction (MAE) has been evaluated as an alternative to dialysis for extraction of some water-borne hydrophobic contaminants sampled by semi-permeable membrane devices (SPMDs). Seven organochlorine pesticides (OCPs), 11 polychlorinated biphenyls (PCBs) and 13 polycyclic aromatic hydrocarbons (PAHs) were accumulated in SPMDs at nanogram levels and extracted with three 3-min irradiation cycles with 33 mL of a solvent mixture hexane-water (10:1,v/v) in each cycle. The developed MAE method gave for all analytes investigated statistically comparable extraction yields with those found by dialysis carried out with a total volume of 250 mL hexane for 48 h at room temperature. The recoveries of all the targeted contaminants were in the range of 65-105% with variation coefficients not exceeding 19%. The applicability of the MAE extraction was tested in field SPMDs samples deployed for 15 days in a sewage-treatment process. Our results show that MAE provides a remarkable reduction of time and solvent volume when used as an extraction method in the analysis of SPMDs. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:355 / 366
页数:12
相关论文
共 35 条
[1]   Polychlorinated biphenyls and hexachlorobenzene in atmosphere, sea-surface microlayer, and water measured with semi-permeable membrane devices (SPMDs) [J].
Booij, K ;
van Drooge, BL .
CHEMOSPHERE, 2001, 44 (02) :91-98
[2]   Determination of aqueous concentrations of polycyclic aromatic hydrocarbons (PAHs) in an urban stream [J].
Crunkilton, RL ;
DeVita, WM .
CHEMOSPHERE, 1997, 35 (07) :1447-1463
[3]  
Dean J., 1998, EXTRACTION METHODS E
[4]  
ELLIS GS, 1995, ENVIRON TOXICOL CHEM, V14, P1875, DOI [10.1897/1552-8618(1995)14[1875:EOLSMD]2.0.CO
[5]  
2, 10.1002/etc.5620141109]
[6]  
*EPA, 3640 EPA
[7]   MICROWAVE EXTRACTION - A NOVEL SAMPLE PREPARATION METHOD FOR CHROMATOGRAPHY [J].
GANZLER, K ;
SALGO, A ;
VALKO, K .
JOURNAL OF CHROMATOGRAPHY, 1986, 371 :299-306
[8]  
GARDINER PW, 1997, STAT ANAL METHODS CH
[9]   Comparison of sampling techniques and evaluation of semipermeable membrane devices (SPMDs) for monitoring polynuclear aromatic hydrocarbons (PAHs) in groundwater [J].
Gustavson, KE ;
Harkin, JM .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (20) :4445-4451
[10]  
Huckins J.N., 1996, Techniques in aquatic toxicology