Testing of different true coincidence correction approaches for gamma-ray spectrometry of voluminous sources

被引:16
作者
Kolotov, VP [1 ]
Koskelo, MJ
机构
[1] Russian Acad Sci, VI Vernadskii Inst Geochem & Analyt Chem, Moscow 117975, Russia
[2] Canberra Ind, Meriden, CT 06450 USA
基金
俄罗斯基础研究基金会;
关键词
HPGe Detector; Efficiency Curve; Peak Efficiency; Efficiency Calibration; Special Calibration;
D O I
10.1007/BF02389653
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
To achieve the highest possible sensitivity of analysis for environmental samples it is common practice to use both a high efficiency detector and a close measurement geometry with a large sample size (e.g. Marinelli beaker). Under such conditions, the typical efficiency calibration procedure results in a biased activity value for many nuclides due to the true coincidence summing effect. While there are a few methods to correct for this effect with special calibration standards, such calibrations can be both time consuming and expensive. Due to these calibration difficulties, the true coincidence summing effect is often simply ignored. Recently, it has been demonstrated that the coincidence summing correction can be performed mathematically even for voluminous sources. This new method consists of an integration of the coincidence correction factor over the sample volume while taking into account its chemical composition and the container. In this paper, we will discuss the latest approaches for establishing the peak efficiency and peak-to-total efficiency curves, which are required for this method. These approaches have been tested for HPGe detectors of two different relative efficiencies.
引用
收藏
页码:95 / 100
页数:6
相关论文
共 13 条
[1]  
Andreev D. S., 1972, Instruments and Experimental Techniques, V15, P1358
[2]  
ANDREEV DS, 1973, IZV AN SSSR FIZ+, V37, P1609
[3]   CORRECTION COEFFICIENT COMPUTATION FOR DETERMINATION OF VOLUMINOUS SOURCE ABSOLUTE RADIOACTIVITY [J].
ATRASHKEVICH, VV ;
KOLOTOV, VP .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1993, 169 (02) :397-408
[4]  
Briesmeister J. F., 1993, LA12625M
[5]  
BRONSON FL, 1997, 5 NDA NDE WAST CHAR
[6]   COINCIDENCE SUMMING CORRECTIONS IN GE(LI)-SPECTROMETRY AT LOW SOURCE-TO-DETECTOR DISTANCES [J].
DEBERTIN, K ;
SCHOTZIG, U .
NUCLEAR INSTRUMENTS & METHODS, 1979, 158 (2-3) :471-477
[7]   THE CORRECTION FOR GAMMA-GAMMA,GAMMA-KX AND GAMMA-LX TRUE-COINCIDENCES IN K(0)-STANDARDIZED NAA WITH COUNTING IN A LEPD [J].
DECORTE, F ;
FREITAS, MC .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1992, 160 (01) :253-267
[8]  
FREITAS C, 1990, BIOL TRACE ELEMENT R, P33
[9]  
GUNNINK R, 1994, MARC3 C 1994
[10]   Estimation of true coincidence corrections for voluminous sources [J].
Kolotov, VP ;
Atrashkevich, VV ;
Gelsema, SJ .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1996, 210 (01) :183-196