Renal blood flow measurements with use of phase-contrast magnetic resonance imaging: Normal values and reproducibility

被引:42
作者
Bax, L
Bakker, CJG
Klein, WM
Blanken, N
Beutler, JJ
Mali, WPTRM
机构
[1] Univ Utrecht, Med Ctr, Dept Radiol, NL-3584 CX Utrecht, Netherlands
[2] Univ Utrecht, Med Ctr, Dept Nephrol, NL-3584 CX Utrecht, Netherlands
关键词
D O I
10.1097/01.RVI.0000161144.98350.28
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To assess the validity and the direct, short-term, and long-term reproducibility of renal blood flow (RBF) measurements with phase-contrast (PC) magnetic resonance (MR) imaging. MATERIALS AND METHODS: In 20 healthy volunteers, RBF measurements were repeated with and without repositioning. Internal validity was assessed by comparing the total RBF with the difference in aortic flow above and below the renal arteries. In 19 healthy volunteers, RBF measurements were performed at two different occasions. In 40 healthy volunteers, RBF measurements were performed to assess normal values as a function of age. Analyses were performed according to Bland and Altman. RESULTS: The technical success rate ranged from 78% to 85%. Total RBF and the difference in aortic flow rates showed good agreement (Pearson correlation coefficient, 0.72; P =.002). Directly repeated measurements had a mean difference of 54 mL/min in total RBF with a coefficient of variation (CV) of 17%. For repeated measurements with repositioning, the mean difference in total RBF was 74 mL/min (CV, 23%). Repeated measurements on different occasions showed a CV of 20%. The mean total RBF of the 40 healthy volunteers was 838 mL/min +/- 244 (SD). CONCLUSIONS: RBF measurement with PC MR has a success rate greater than 75%. The demonstrated internal reliability of this method and fair reproducibility of the flow parameters is crucial for further studies of the renal artery with MR imaging.
引用
收藏
页码:807 / 814
页数:8
相关论文
共 29 条
[1]   Renal volume measurements: Accuracy and repeatability of US compared with that of MR imaging [J].
Bakker, J ;
Olree, M ;
Kaatee, R ;
de Lange, EE ;
Moons, KGM ;
Beutler, JJ ;
Beek, FJA .
RADIOLOGY, 1999, 211 (03) :623-628
[2]   Colour Doppler ultrasound in renal artery stenosis: Intrarenal waveform analysis [J].
Baxter, GM ;
Aitchison, F ;
Sheppard, D ;
Moss, JG ;
McLeod, MJ ;
Harden, PN ;
Love, JG ;
Robertson, M ;
Taylor, G .
BRITISH JOURNAL OF RADIOLOGY, 1996, 69 (825) :810-815
[3]   Can MR measurement of renal artery flow and renal volume predict the outcome of percutaneous transluminal renal angioplasty? [J].
Binkert, CA ;
Debatin, JF ;
Schneider, E ;
Hodler, J ;
Ruehm, SG ;
Schmidt, M ;
Hoffmann, U .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2001, 24 (04) :233-239
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   ULTRASOUND QUANTITATION OF RESPIRATORY ORGAN MOTION IN THE UPPER ABDOMEN [J].
DAVIES, SC ;
HILL, AL ;
HOLMES, RB ;
HALLIWELL, M ;
JACKSON, PC .
BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (803) :1096-1102
[6]   Renovascular disease in patients with hypertension: detection with duplex ultrasound [J].
de Haan, MW ;
Kroon, AA ;
Flobbe, K ;
Kessels, AGH ;
Tordoir, JH ;
van Engelshoven, JMA ;
de Leeuw, PW .
JOURNAL OF HUMAN HYPERTENSION, 2002, 16 (07) :501-507
[7]   Renal artery blood flow: quantification with breath-hold or respiratory triggered phase-contrast MR imaging [J].
de Haan, MW ;
Kouwenhoven, M ;
Kessels, AGH ;
van Engelshoven, JMA .
EUROPEAN RADIOLOGY, 2000, 10 (07) :1133-1137
[8]   RENAL-ARTERY BLOOD-FLOW - QUANTITATION WITH PHASE-CONTRAST MR-IMAGING WITH AND WITHOUT BREATH-HOLDING [J].
DEBATIN, JF ;
TING, RH ;
WEGMULLER, H ;
SOMMER, FG ;
FREDRICKSON, JO ;
BROSNAN, TJ ;
BOWMAN, BS ;
MYERS, BD ;
HERFKENS, RJ ;
PELC, NJ .
RADIOLOGY, 1994, 190 (02) :371-378
[9]   MR quantification of flow in abdominal vessels [J].
Debatin, JF .
ABDOMINAL IMAGING, 1998, 23 (05) :485-495
[10]   Renovascular disease in patients with hypertension: Detection with systolic and diastolic gating in three-dimensional, phase-contrast MR angiography [J].
deHaan, MW ;
Kouwenhoven, M ;
Thelissen, GRP ;
Koster, D ;
Kessels, AGH ;
deLeeuw, PW ;
vanEngelshoven, JMA .
RADIOLOGY, 1996, 198 (02) :449-456