Automated Quantitative Bone Analysis in In Vivo X-ray Micro-Computed Tomography

被引:11
作者
Behrooz, Ali [1 ]
Kask, Peet [1 ]
Meganck, Jeff [1 ]
Kempner, Joshua [1 ]
机构
[1] PerkinElmer Inc, Hopkinton, MA 01748 USA
关键词
Bone morphometry; hybrid thresholding; medial axis; object segmentation; splitting filters; stereological measurements; automated bone analysis; X-ray computed tomography; HISTOLOGICAL SECTIONS; CT; MODEL; SEGMENTATION; ARCHITECTURE; MICROSTRUCTURE; ANIMALS; RATS;
D O I
10.1109/TMI.2017.2712571
中图分类号
TP39 [计算机的应用];
学科分类号
080201 [机械制造及其自动化];
摘要
Measurement and analysis of bone morphometry in 3D micro-computed tomography volumes using automated image processing and analysis improve the accuracy, consistency, reproducibility, and speed of preclinical osteological research studies. Automating segmentation and separation of individual bones in 3D microcomputed tomography volumes of murine models presents significant challenges considering partial volume effects and joints with thin spacing, i.e., 50 to 100 mu m. In this paper, novel hybrid splitting filters are presented to overcome the challenge of automated bone separation. This is achieved by enhancing joint contrast using rotationally invariant second-derivative operators. These filters generate split components that seed marker-controlled watershed segmentation. In addition, these filters can be used to separate metaphysis and epiphysis in long bones, e.g., femur, and remove the metaphyseal growth plate from the detected bone mask in morphometric measurements. Moreover, for slice-by-slice stereological measurements of long bones, particularly curved bones, such as tibia, the accuracy of the analysis can be improved if the planar measurements are guided to follow the longitudinal direction of the bone. In this paper, an approach is presented for characterizing the bone medial axis using morphological thinning and centerline operations. Building upon the medial axis, a novel framework is presented to automatically guide stereological measurements of long bones and enhance measurement accuracy and consistency. These image processing and analysis approaches are combined in an automated streamlined software workflow and applied to a range of in vivo micro-computed tomography studies for validation.
引用
收藏
页码:1955 / 1965
页数:11
相关论文
共 40 条
[1]
AnalyzeDirect Inc, BON MICR AN ADD ON
[2]
Bab I., 2007, MICROTOMOGRAPHIC ATL
[3]
The use of micro-CT to evaluate cortical bone geometry and strength in nude rats: Correlation with mechanical testing, pQCT and DXA [J].
Bagi, CM ;
Hanson, N ;
Andresen, C ;
Pero, R ;
Lariviere, R ;
Turner, CH ;
Laib, A .
BONE, 2006, 38 (01) :136-144
[4]
Beucher S., 1993, MATH MORPHOLOGY IMAG, V34, P433, DOI DOI 10.1201/9781482277234-12
[5]
Botter SM, 2006, BIORHEOLOGY, V43, P379
[6]
Guidelines for Assessment of Bone Microstructure in Rodents Using Micro-Computed Tomography [J].
Bouxsein, Mary L. ;
Boyd, Stephen K. ;
Christiansen, Blaine A. ;
Guldberg, Robert E. ;
Jepsen, Karl J. ;
Mueller, Ralph .
JOURNAL OF BONE AND MINERAL RESEARCH, 2010, 25 (07) :1468-1486
[7]
Automatic segmentation of cortical and trabecular compartments based on a dual threshold technique for in vivo micro-CT bone analysis [J].
Buie, Helen R. ;
Campbell, Graeme M. ;
Klinck, R. Joshua ;
MacNeil, Joshua A. ;
Boyd, Steven K. .
BONE, 2007, 41 (04) :505-515
[8]
Signs of irreversible architectural changes occur early in the development of experimental osteoporosis as assessed by in vivo micro-CT [J].
Campbell, G. M. ;
Buie, H. R. ;
Boyd, S. K. .
OSTEOPOROSIS INTERNATIONAL, 2008, 19 (10) :1409-1419
[9]
Noninvasive in vivo monitoring of bone architecture alterations in hindlimb-unloaded female rats using novel three-dimensional microcomputed tomography [J].
David, V ;
Laroche, N ;
Boudignon, B ;
Lafage-Proust, MH ;
Alexandre, C ;
Ruegsegger, P ;
Vico, L .
JOURNAL OF BONE AND MINERAL RESEARCH, 2003, 18 (09) :1622-1631
[10]
A GENERAL-APPROACH TO CONNECTED-COMPONENT LABELING FOR ARBITRARY IMAGE REPRESENTATIONS [J].
DILLENCOURT, MB ;
SAMET, H ;
TAMMINEN, M .
JOURNAL OF THE ACM, 1992, 39 (02) :253-280