Optimisation and validation of a sensitive high-performance liquid chromatography assay for routine measurement of pyridoxal 5-phosphate in human plasma and red cells using pre-column semicarbazide derivatisation

被引:96
作者
Talwar, D [1 ]
Quasim, T
McMillan, DC
Kinsella, J
Williamson, C
O'Reilly, DS
机构
[1] Royal Infirm, Dept Biochem, Glasgow G31 2ER, Lanark, Scotland
[2] Univ Glasgow, Royal Infirm, Dept Surg, Glasgow G31 2ER, Lanark, Scotland
[3] Univ Glasgow, Royal Infirm, Dept Anaesthesia, Glasgow G31 2ER, Lanark, Scotland
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2003年 / 792卷 / 02期
关键词
optimisation; validation; derivitisation; LC; vitamins; pyridoxal; 5-phosphate;
D O I
10.1016/S1570-0232(03)00320-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
There are few studies in which direct measurement of vitamin B6 status in both plasma and red cells has been assessed. The aims of the present study were to evaluate the use of a simple, robust HPLC method of direct pyridoxal 5'-phosphate (PLP) measurement in plasma and red cells and to assess its use in establishing reference ranges in a healthy population. A reverse phase HPLC method with pre-column derivatisation using semicarbazide for the simultaneous measurement of PLP, its degradation product, 4-pyridoxic acid (PA) and pyridoxal (PL) in plasma and red cells was developed. Pre-column derivatisation, reverse phase chromatography and detection procedures were optimised. The recovery, precision, linearity and sensitivity of the assay for plasma and red cell PLP, PA and PL was established. The recovery of PLP was greater than 95% for both plasma and red cell samples. The Intra and Inter batch imprecision for PLP was less than 6% and 7%, respectively. The method for PLP was linear up to at least 1000 nmol/l and the detection limit was 2.1 nmol/l (limit of quantification; 5.8 nmol/l). Accuracy of PLP measurements in plasma were acceptable, showing a mean bias of 4.5% from the mean value of laboratories (N=34) participating in an external quality assurance scheme. Geometric mean (95% reference intervals) for plasma and red cell PLP in the healthy subjects (N=126) were 56 (21-138) nmol/l and 410 (250-680) pmol/g Hb, respectively. There was a strong positive correlation (r(2)=0.81) between plasma and red cell PLP levels in the reference population. The HPLC method described was found to be suitable for the routine measurement of PLP in both plasma and red cells. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:333 / 343
页数:11
相关论文
共 27 条
[1]  
[Anonymous], 1981, Methods in Vitamin B-6 Nutrition
[2]  
[Anonymous], 1981, METHODS VITAMIN B6 N
[3]  
[Anonymous], 1991, HDB VITAMINS
[4]   High performance liquid chromatography method for the determination of pyridoxal-5-phosphate in human plasma:: How appropriate are cut-off values for vitamin B6 deficiency? [J].
Bailey, AL ;
Wright, AJA ;
Southon, S .
EUROPEAN JOURNAL OF CLINICAL NUTRITION, 1999, 53 (06) :448-455
[5]   A simple, sensitive and reproducible assay for pyridoxal 5′-phosphate and 4-pyridoxic acid in human plasma [J].
Bates, CJ ;
Pentieva, KD ;
Matthews, N ;
Macdonald, A .
CLINICA CHIMICA ACTA, 1999, 280 (1-2) :101-111
[6]   Vitamin analysis [J].
Bates, CJ .
ANNALS OF CLINICAL BIOCHEMISTRY, 1997, 34 :599-626
[7]   SEMICARBAZONE FORMATION FROM PYRIDOXAL, PYRIDOXAL PHOSPHATE, AND THEIR SCHIFF BASES [J].
CORDES, EH ;
JENCKS, WP .
BIOCHEMISTRY, 1962, 1 (05) :773-&
[8]   CHARACTERISTICS OF PYRIDOXINE OVERDOSE NEUROPATHY SYNDROME [J].
DALTON, K ;
DALTON, MJT .
ACTA NEUROLOGICA SCANDINAVICA, 1987, 76 (01) :8-11
[9]   Clinical adaptation of a high-performance liquid chromatographic method for the assay of pyridoxal 5′-phosphate in human plasma [J].
Deitrick, CL ;
Katholi, RE ;
Huddleston, DJ ;
Hardiek, K ;
Burrus, L .
JOURNAL OF CHROMATOGRAPHY B, 2001, 751 (02) :383-387
[10]  
EDWARDS P, 1989, CLIN CHEM, V35, P241