Cesium coherent population trapping magnetometer for cardiosignal detection in an unshielded environment

被引:66
作者
Belfi, J.
Bevilacqua, G.
Biancalana, V.
Cartaleva, S.
Dancheva, Y.
Moi, L.
机构
[1] Univ Siena, CNISM Unita Siena, Dipartimento Fis, I-53100 Siena, Italy
[2] Univ Siena, CNISM Unita Siena, Dipartimento Ingn Informaz, I-53100 Siena, Italy
[3] Bulgarian Acad Sci, Inst Elect, BU-1784 Sofia, Bulgaria
关键词
D O I
10.1364/JOSAB.24.002357
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We present encouraging results obtained with an experimental apparatus based on coherent population trapping and aimed at detecting a biological (cardiac) magnetic field in a magnetically compensated but unshielded volume. The work includes magnetic-field and magnetic-field-gradient compensation and uses differential detection to cancel common mode magnetic noise. Synchronous data acquisition with a reference (electrocardiographic or pulse-oximetric) signal makes possible improvement of the signal-to-noise ratio in off-line averaging. The setup has the significant advantages of working at room temperature with a small-size head, and the possibility of fast adjustments of the de bias magnetic field, which makes the sensor suitable for detecting a biomagnetic signal at any orientation with respect to the axis of the head and in any position on the patient's chest, which is not the case with other kinds of magnetometers. (c) 2007 Optical Society of America.
引用
收藏
页码:2357 / 2362
页数:6
相关论文
共 16 条
[1]   Nonlinear magneto-optical rotation with frequency-modulated light in the geophysical field range [J].
Acosta, V. ;
Ledbetter, M. P. ;
Rochester, S. M. ;
Budker, D. ;
Kimball, D. F. Jackson ;
Hovde, D. C. ;
Gawlik, W. ;
Pustelny, S. ;
Zachorowski, J. ;
Yashchuk, V. V. .
PHYSICAL REVIEW A, 2006, 73 (05)
[2]   An all-optical, high-sensitivity magnetic gradiometer [J].
Affolderbach, C ;
Stähler, M ;
Knappe, S ;
Wynands, R .
APPLIED PHYSICS B-LASERS AND OPTICS, 2002, 75 (6-7) :605-612
[3]   High-sensitivity atomic magnetometer unaffected by spin-exchange relaxation [J].
Allred, JC ;
Lyman, RN ;
Kornack, TW ;
Romalis, MV .
PHYSICAL REVIEW LETTERS, 2002, 89 (13) :130801-130801
[4]   Two-color coherent population trapping in a single Cs hyperfine transition, with application in magnetometry [J].
Andreeva, C ;
Bevilacqua, G ;
Biancalana, V ;
Cartaleva, S ;
Dancheva, Y ;
Karaulanov, T ;
Marinelli, C ;
Mariotti, E ;
Moi, L .
APPLIED PHYSICS B-LASERS AND OPTICS, 2003, 76 (06) :667-675
[5]   All optical sensor for automated magnetometry based on coherent population trapping [J].
Belfi, J. ;
Bevilacqua, G. ;
Biancalana, V. ;
Dancheva, Y. ;
Moi, L. .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2007, 24 (07) :1482-1489
[6]   Dynamical mapping of the human cardiomagnetic field with a room-temperature, laser-optical sensor [J].
Bison, G ;
Wynands, R ;
Weis, A .
OPTICS EXPRESS, 2003, 11 (08) :904-909
[7]   A laser-pumped magnetometer for the mapping of human cardiomagnetic fields [J].
Bison, G ;
Wynands, R ;
Weis, A .
APPLIED PHYSICS B-LASERS AND OPTICS, 2003, 76 (03) :325-328
[8]   PRINCIPLES OF OPERATION OF THE RUBIDIUM VAPOR MAGNETOMETER [J].
BLOOM, AL .
APPLIED OPTICS, 1962, 1 (01) :61-68
[9]   Resonant nonlinear magneto-optical effects in atoms [J].
Budker, D ;
Gawlik, W ;
Kimball, DF ;
Rochester, SM ;
Yashchuk, VV ;
Weis, A .
REVIEWS OF MODERN PHYSICS, 2002, 74 (04) :1153-1201
[10]   Nonlinear magneto-optical rotation with frequency-modulated light [J].
Budker, D ;
Kimball, DF ;
Yashchuk, VV ;
Zolotorev, M .
PHYSICAL REVIEW A, 2002, 65 (05) :4