Biomechanical comparisons of three different tibial tunnel directions in posterior cruciate ligament reconstruction

被引:46
作者
Kim, SJ
Shin, JW [1 ]
Lee, CH
Shin, HJ
Kim, SH
Jeong, JH
Lee, JW
机构
[1] Inje Univ, Dept Biomed Engn, Gimhae, South Korea
[2] Yonsei Univ, Dept Orthopaed Surg, Coll Med, Seoul 120749, South Korea
[3] Yonsei Univ, Brain Korea Project Med Sci 21, Seoul 120749, South Korea
基金
新加坡国家研究基金会;
关键词
posterior cruciate ligament reconstruction; finite element analysis; viscoelastic properties; cadaveric experiments;
D O I
10.1016/j.arthro.2004.11.004
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To investigate the effects of 3 different tunnel directions on the outcomes of posterior cruciate ligament (PCL) reconstruction surgery based on the forces exerted on the replacement ligament from a biomechanical point of view. The 3 tunnel directions in the proximal tibia are medial, central, and lateral. Type of Study: Biomechanical study. Methods: The forces exerted on the replaced PCL were calculated using finite element analyses as well as measurements from 6 cadavers. The results of the 3 surgical approaches were then compared. In the finite element analyses, the replaced ligament was assumed to have nonlinear elastic as well as viscoelastic properties. To simulate the overload in exercise, the femur was forced to move in the anterior direction abruptly while the tibia was held. From numerical analyses, the resultant forces, von Mises stresses, and maximum shear stresses on the replacement PCLs were calculated and compared. In the cadaveric study, a pressure-sensitive thin film was inserted between the replacement PCL and the killer turn area of the tibia. The color changes in films were evaluated using digital image processing in each case. Results: The medial approach showed remarkably higher stresses and forces on the interface between the replaced PCL and the killer turn in both the numerical and cadaveric study. In contrast, the lateral approach showed the lowest stresses. Conclusions: The numerical and cadaveric studies indicate that the lateral approach is highly promising compared with the other approaches. Clinical Relevance: The lateral approach has been shown to minimize stress concentration around the killer turn during in vitro experiments and a computer simulation of PCL reconstruction for long-term stability. The lateral approach technique appears to provide a promising clinical outcome in patients undergoing PCL reconstruction.
引用
收藏
页码:286 / 293
页数:8
相关论文
共 17 条
[1]
POSTERIOR CRUCIATE LIGAMENT TIBIAL INLAY RECONSTRUCTION [J].
BERG, EE .
ARTHROSCOPY, 1995, 11 (01) :69-76
[2]
LIGAMENT-BONE INTERACTION IN A 3-DIMENSIONAL MODEL OF THE KNEE [J].
BLANKEVOORT, L ;
HUISKES, R .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1991, 113 (03) :263-269
[3]
COMPARISON OF MATERIAL PROPERTIES IN FASCICLE-BONE UNITS FROM HUMAN PATELLAR TENDON AND KNEE LIGAMENTS [J].
BUTLER, DL ;
KAY, MD ;
STOUFFER, DC .
JOURNAL OF BIOMECHANICS, 1986, 19 (06) :425-432
[4]
FENTON PJ, 1994, SPORTS MED ARTHROSC, V2, P129
[5]
HANS U, 1999, AM J SPORTS MED, V27, P27
[6]
THE HUMAN POSTERIOR CRUCIATE LIGAMENT COMPLEX - AN INTERDISCIPLINARY STUDY - LIGAMENT MORPHOLOGY AND BIOMECHANICAL EVALUATION [J].
HARNER, CD ;
XEROGEANES, JW ;
LIVESAY, GA ;
CARLIN, GJ ;
SMITH, BA ;
KUSAYAMA, T ;
KASHIWAGUCHI, S ;
WOO, SLY .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1995, 23 (06) :736-745
[7]
THE VISCOELASTIC DEFORMATION OF TENDON [J].
HOOLEY, CJ ;
MCCRUM, NG ;
COHEN, RE .
JOURNAL OF BIOMECHANICS, 1980, 13 (06) :521-528
[8]
ARTHROSCOPIC INTRAARTICULAR INTERFERENCE SCREW TECHNIQUE OF POSTERIOR CRUCIATE LIGAMENT RECONSTRUCTION - ONE-INCISION TECHNIQUE [J].
KIM, SJ ;
MIN, BH .
ARTHROSCOPY, 1994, 10 (03) :319-323
[9]
Comparison of 1-and 2-incision posterior cruciate ligament reconstructions [J].
Kim, SJ ;
Shin, SJ ;
Kim, HK ;
Jahng, JS ;
Kim, HS .
ARTHROSCOPY, 2000, 16 (03) :268-278
[10]
A validated three-dimensional computational model of a human knee joint [J].
Li, G ;
Gil, J ;
Kanamori, A ;
Woo, SLY .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1999, 121 (06) :657-662