New, sensitive and selective method for determining sub-μg/l levels of bromate in drinking water

被引:27
作者
Weinberg, HS [1 ]
Yamada, H
Joyce, RJ
机构
[1] Univ N Carolina, Dept Environm Sci & Engn, Chapel Hill, NC 27599 USA
[2] Kyoto Univ, Fac Engn, Res Ctr Environm Qual Control, Otsu, Shiga 520, Japan
[3] Dionex Corp, Sunnyvale, CA 94088 USA
关键词
water analysis; bromate; inorganic anions;
D O I
10.1016/S0021-9673(98)00152-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Health effects studies suggest that bromate should be regulated at 0.5 mu g/l or less in drinking water. Accordingly, an analytical method is needed to quantify this contaminant with great sensitivity and selectivity. Past efforts to do this have focused on pre-concentration ion chromatographic (IC) separation followed by suppressed conductivity detection. Interfering chloride was removed by passing samples over a silver resin which increased sample analysis time to almost 1 h. Tn this paper, a new method which uses IC separation with no pre-treatment followed by a post-column reaction to produce tribromide (Br-3(-)) from bromate, is applied to the analysis of a variety of aqueous samples. The tribromide ion is detected by UV absorbance at 267 nm. This method is very sensitive for bromate with a limit of quantitation of 0.2 mu g/l and is also very selective. Common anions typically separated by IC exhibit no interference, even at the levels normally found in drinking water. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:137 / 142
页数:6
相关论文
共 19 条
[1]  
Amy G., 1994, SURVEY BROMIDE DRINK
[2]  
[Anonymous], 1991, HLTH EFFECTS DISINFE
[3]   OCCURRENCE OF CHLORATE IN HYPOCHLORITE SOLUTIONS USED FOR DRINKING-WATER DISINFECTION [J].
BOLYARD, M ;
FAIR, PS ;
HAUTMAN, DP .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1992, 26 (08) :1663-1665
[4]  
CRECELIUS EA, 1978, OZONE NEWS, V5, P1
[5]   Determination of bromate in the presence of brominated haloacetic acids by ion chromatography with inductively coupled plasma mass spectrometric detection [J].
Creed, JT ;
Magnuson, ML ;
Brockhoff, CA .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1997, 31 (07) :2059-2063
[6]  
FIELDING M, 1993, P INT WORKSH BROM WA
[7]   THE MEASUREMENT OF VERY-LOW LEVEL BROMATE ION [J].
GORDON, G ;
BUBNIS, B .
OZONE-SCIENCE & ENGINEERING, 1995, 17 (05) :551-559
[8]  
HAUTMAN D, 1992, AWWA WQTC TOR
[9]   High selective determination of bromate in ozonized water by using ion chromatography with postcolumn derivatization equipped with reagent preparation device [J].
Inoue, Y ;
Sakai, T ;
Kumagai, H ;
Hanaoka, Y .
ANALYTICA CHIMICA ACTA, 1997, 346 (03) :299-305
[10]  
JOYCE RL, 1997, INT ION CHROM S SANT