Adverse effect of ventricular pacing on heart failure and atrial fibrillation among patients with normal baseline QRS duration in a clinical trial of pacemaker therapy for sinus node dysfunction

被引:1416
作者
Sweeney, MO
Hellkamp, AS
Ellenbogen, KA
Greenspon, AJ
Freedman, RA
Lee, KL
Lamas, GA
机构
[1] Brigham & Womens Hosp, Cardiac Arrhythmia Serv, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] Duke Clin Res Inst, Durham, NC USA
[4] Duke Univ, Sch Med, Durham, NC USA
[5] Virginia Commonwealth Univ, Med Coll Virginia, Richmond, VA 23298 USA
[6] Thomas Jefferson Univ, Jefferson Med Coll, Philadelphia, PA 19107 USA
[7] Univ Utah, Hlth Sci Ctr, Salt Lake City, UT USA
[8] Mt Sinai Med Ctr, Miami, FL USA
关键词
pacing; heart failure; fibrillation;
D O I
10.1161/01.CIR.0000072769.17295.B1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Dual-chamber (DDDR) pacing preserves AV synchrony and may reduce heart failure (HF) and atrial fibrillation (AF) compared with ventricular (VVIR) pacing in sinus node dysfunction (SND). However, DDDR pacing often results in prolonged QRS durations (QRSd) as the result of right ventricular stimulation, and ventricular desynchronization may result. The effect of pacing-induced ventricular desynchronization in patients with normal baseline QRSd is unknown. Methods and Results-Baseline QRSd was obtained from 12-lead ECGs before pacemaker implantation in MOST, a 2010-patient, 6-year, randomized trial of DDDR versus VVIR pacing in SND. Cumulative percent ventricular paced (Cum%VP) was determined from stored pacemaker data. Baseline QRSd <120 ms was observed in 1339 patients (707 DDDR, 632 VVIR). Cum%VP was greater in DDDR versus VVIR (90% versus 58%, P = 0.001). Cox models demonstrated that the time-dependent covariate Cum%VP was a strong predictor of HF hospitalization in DDDR (hazard ratio [HR], 2.99 [95% CI, 1.15 to 7.75] for Cum%VP >40%) and VVIR (HR 2.56 [95% CI, 1.48 to 4.43] for Cum%VP >80%). The risk of AF increased linearly with Cum%VP from 0% to 85% in both groups (DDDR, HR 1.36 [95% CI, 1.09, 1.69]; VVIR, HR 1.21 [95% CI 1.02, 1.43], for each 25% increase in Cum%VP). Model results were unaffected by adjustment for known baseline predictors of HF hospitalization and AF. Conclusions-Ventricular desynchronization imposed by ventricular pacing even when AV synchrony is preserved increases the risk of HF hospitalization and AF in SND with normal baseline QRSd.
引用
收藏
页码:2932 / 2937
页数:6
相关论文
共 22 条
  • [1] MYOFIBRILLAR DISARRAY PRODUCED IN NORMAL HEARTS BY CHRONIC ELECTRICAL PACING
    ADOMIAN, GE
    BEAZELL, J
    [J]. AMERICAN HEART JOURNAL, 1986, 112 (01) : 79 - 83
  • [2] Long-term follow-up of patients from a randomised trial of atrial versus ventricular pacing for sick-sinus syndrome
    Andersen, HR
    Nielsen, JC
    Thomsen, PEB
    Thuesen, L
    Mortensen, PT
    Vesterlund, T
    Pedersen, AK
    [J]. LANCET, 1997, 350 (9086) : 1210 - 1216
  • [3] [Anonymous], MODELING SURVIVAL DA
  • [4] Effects of physiologic pacing versus ventricular pacing on the risk of stroke and death due to cardiovascular causes
    Connolly, SJ
    Kerr, CR
    Gent, M
    Roberts, RS
    Yusuf, S
    Gillis, AM
    Sami, MH
    Talajic, M
    Tang, ASL
    Klein, GJ
    Lau, C
    Newman, DM
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2000, 342 (19) : 1385 - 1391
  • [5] COX DR, 1972, J R STAT SOC B, V34, P187
  • [6] JANOSIK DL, 2000, CLIN CARDIAC PACING, P333
  • [7] NONPARAMETRIC-ESTIMATION FROM INCOMPLETE OBSERVATIONS
    KAPLAN, EL
    MEIER, P
    [J]. JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1958, 53 (282) : 457 - 481
  • [8] KARNOFSKY DA, 1948, CANCER-AM CANCER SOC, V1, P634, DOI 10.1002/1097-0142(194811)1:4<634::AID-CNCR2820010410>3.0.CO
  • [9] 2-L
  • [10] DEVELOPMENTAL SEQUELAE OF FIXED-RATE VENTRICULAR PACING IN THE IMMATURE CANINE HEART - AN ELECTROPHYSIOLOGIC, HEMODYNAMIC, AND HISTOPATHOLOGIC EVALUATION
    KARPAWICH, PP
    JUSTICE, CD
    CAVITT, DL
    CHANG, CH
    [J]. AMERICAN HEART JOURNAL, 1990, 119 (05) : 1077 - 1083