Baseband velocity estimation for second-harmonic signals exploiting the invariance of the Doppler equation

被引:3
作者
Verbeek, XAAM [1 ]
Ledoux, LAF [1 ]
Brands, PJ [1 ]
Hoeks, APG [1 ]
机构
[1] Maastricht Univ, Inst Cardiovasc Res, Dept Biophys, NL-6200 MD Maastricht, Netherlands
关键词
baseband estimation; computational load; Doppler equation invariance; RF domain processing; second-harmonic; ultrasound signals; virtual RF demodulation and decimation;
D O I
10.1109/10.720199
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
All Doppler systems, whether conventional Doppler domain or radio frequency (RF) processing is employed, relate the temporal frequency characteristics of the signal at a certain point in depth as function of time to the spatial frequency characteristics of the received signal as function of depth. The mean frequency of the latter may change as a result of depth-dependent attenuation, nonlinear scattering mechanisms, as in harmonic imaging of ultrasound contrast agents, or RF signal demodulation. For all these cases, the relationship between spatial and temporal mean frequency and target velocity is still governed by the familiar Doppler expression if the signal modifications have been properly accounted for. A major drawback of RF signal processing to extract the target velocity is the large number of data points to consider. The computational complexity increases further for harmonic imaging. It is shown conceptually, and demonstrated by signal simulations, that prior to velocity estimation RP demodulation followed by decimation 1) does not affect the Doppler equation, 2) enhances the information content of the samples, 3) reduces the computational load by a factor of four and for harmonic signals by a higher factor, and 4) while demodulation does not have to be actually performed, but can be accounted for by a scaling factor in the cross-correlation function. It is concluded that decimation hardly affects the precision of the velocity estimate if possible frequency aliasing is maintained within bounds, suggesting that the decimation factor is not critical.
引用
收藏
页码:1217 / 1226
页数:10
相关论文
共 8 条
[1]   TIME DOMAIN FORMULATION OF PULSE-DOPPLER ULTRASOUND AND BLOOD VELOCITY ESTIMATION BY CROSS-CORRELATION [J].
BONNEFOUS, O ;
PESQUE, P .
ULTRASONIC IMAGING, 1986, 8 (02) :73-85
[2]   A radio frequency domain complex cross-correlation model to estimate blood flow velocity and tissue motion by means of ultrasound [J].
Brands, PJ ;
Hoeks, APG ;
Ledoux, LAF ;
Reneman, RS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (06) :911-920
[3]  
CHANG PH, 1995, IEEE T ULTRASON FERR, V42, P1020
[4]  
De Jong N, 1993, ACOUSTIC PROPERTIES
[5]   COMPARISON OF THE PERFORMANCE OF THE RF CROSS-CORRELATION AND DOPPLER AUTOCORRELATION TECHNIQUE TO ESTIMATE THE MEAN VELOCITY OF SIMULATED ULTRASOUND SIGNALS [J].
HOEKS, APG ;
ARTS, TGJ ;
BRANDS, PJ ;
RENEMAN, RS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (09) :727-740
[6]   EFFECT OF SAMPLE WINDOW LENGTH ON THE CORRELATION BETWEEN RF SIGNAL AND PULSED DOPPLER SIGNAL INTENSITY [J].
HOEKS, APG ;
BRANDS, PJ ;
RENEMAN, RS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1994, 20 (01) :35-40
[7]  
HOEKS APG, 1994, EUR J ULTRASOUND, V1, P171
[8]   AN AXIAL VELOCITY ESTIMATOR FOR ULTRASOUND BLOOD-FLOW IMAGING, BASED ON A FULL EVALUATION OF THE DOPPLER EQUATION BY MEANS OF A 2-DIMENSIONAL AUTOCORRELATION APPROACH [J].
LOUPAS, T ;
POWERS, JT ;
GILL, RW .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1995, 42 (04) :672-688