Does Length, Diameter, or Bone Quality Affect Primary and Secondary Stability in Self-Tapping Dental Implants?

被引:57
作者
Gomez-Polo, Miguel [1 ]
Ortega, Rocio [1 ]
Gomez-Polo, Cristina [2 ]
Martin, Cristina [1 ]
Celemin, Alicia [1 ]
del Rio, Jaime [1 ]
机构
[1] Univ Complutense Madrid, Dept Prosthet Dent, Sch Dent, Madrid, Spain
[2] Univ Salamanca, Sch Med, Dept Surg, E-37008 Salamanca, Spain
关键词
RESONANCE FREQUENCY-ANALYSIS; TITANIUM IMPLANTS; INSERTION TORQUE; CORTICAL BONE; CUTTING TORQUE; VALUES; DENSITY; PLACEMENT; THICKNESS;
D O I
10.1016/j.joms.2016.03.011
中图分类号
R78 [口腔科学];
学科分类号
100302 [口腔临床医学];
摘要
Purpose: Implant stability is a clinically valuable measurement of the strength of implant anchorage in the bone during placement and in the post-osseointegration period. This study aimed to determine 1) the effect of implant diameter and length and bone quality on measurements of primary and secondary stability (insertion torque [IT] and implant stability quotient [ISQ]), 2) the correlation between IT and primary and secondary ISQ, and 3) differences in ISQ in the post-osseointegration period (secondary stability) compared with immediate post-placement (primary) stability. Patients and Methods: In this longitudinal clinical study, titanium self-tapping implants were inserted in edentulous patients. The implants were grouped according to 3 independent variables: length (10 and 11.5 mm), diameter (3.75 and 4.25 mm), and bone quality (Lekholm and Zarb classification) to analyze primary and secondary implant stability (outcome variables). Statistical analyses were performed using the Student t test for paired data, 1-way analysis of variance, and the Tukey procedure for multiple pairwise comparisons. Results: Data were collected on 88 self-tapping implants inserted in 63 partially edentulous patients. IT and implant stability were affected by diameter (3.75-mm implants, 26.5-N/cm IT and 74.0 ISQ; 4.25-mm implants, 33.8-N/cm IT and 77.0 ISQ) and bone type (type 1 + 2, 34.86-N/cm IT and 77.4 ISQ; type 3, 27.09-N/cm IT and 75.6 ISQ; type 4, 20.63-N/cm IT and 70.5 ISQ; P<.01 for all comparisons). Secondary ISQ was affected by diameter only (77.41 for 3.75-vs 75.51 for 4.25-mm implants). IT correlated with primary ISQ (R = 0.56; P<.01), although no clear correlation with secondary stability was found. Conclusions: IT and primary ISQ in self-tapping implants differed in patients with different bone quality and implant diameter but did not differ between the 2 implant lengths compared in this study. Secondary stability was not substantially affected by any of these factors. Although IT was closely related to primary ISQ, it was unrelated to secondary ISQ. Very high primary ISQ values tended to decrease, whereas intermediate and low values tended to increase, in the transition to secondary stability. (C) 2016 American Association of Oral and Maxillofacial Surgeons.
引用
收藏
页码:1344 / 1353
页数:10
相关论文
共 40 条
[1]
A biomechanical assessment of the relation between the oral implant stability at insertion and subjective bone quality assessment [J].
Alsaadi, Ghada ;
Quirynen, Marc ;
Michiels, Katleen ;
Jacobs, Reinhilde ;
van Steenberghe, Daniel .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2007, 34 (04) :359-366
[2]
Andersson P., 2008, Appl Osseointegration Res, V6, P23
[3]
Atsumi M, 2007, INT J ORAL MAX IMPL, V22, P743
[4]
Barewal RM, 2012, INT J ORAL MAX IMPL, V27, P945
[5]
Implant Compression Necrosis: Current Understanding and Case Report [J].
Bashutski, Jill D. ;
D'Silva, Nisha J. ;
Wang, Hom-Lay .
JOURNAL OF PERIODONTOLOGY, 2009, 80 (04) :700-704
[6]
Early Loading of Nonsubmerged Titanium Implants with a Chemically Modified Sand-Blasted and Acid-Etched Surface: 6-Month Results of a Prospective Case Series Study in the Posterior Mandible Focusing on Peri-Implant Crestal Bone Changes and Implant Stability Quotient (ISQ) Values [J].
Bornstein, Michael M. ;
Hart, Christopher N. ;
Halbritter, Sandro A. ;
Morton, Dean ;
Buser, Daniel .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2009, 11 (04) :338-347
[7]
Brunski J B, 1999, Adv Dent Res, V13, P99
[8]
Cehreli MC, 2009, INT J ORAL MAX IMPL, V24, P1015
[9]
RFA Values of Implants Placed in Sinus Grafted and Nongrafted Sites after 6 and 12 Months [J].
Degidi, Marco ;
Daprile, Giuseppe ;
Piattelli, Adriano .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2009, 11 (03) :178-182
[10]
Relation between bone density and primary implant stability [J].
Farre-Pages, Nuria ;
Auge-Castro, Ma Luisa ;
Alaejos-Algarra, Fernando ;
Mareque-Bueno, Javier ;
Ferres-Padro, Eduard ;
Hernandez-Alfaro, Federico .
MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2011, 16 (01) :E62-E67