Paracetamol voltammetric microsensors based on electrocopolymerized-molecularly imprinted film modified carbon fiber microelectrodes

被引:76
作者
Gómez-Caballero, A [1 ]
Goicolea, MA [1 ]
Barrio, RJ [1 ]
机构
[1] Univ Basque Country, Fac Pharm, Dept Analyt Chem, Vitoria 01006, Spain
关键词
D O I
10.1039/b502827b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A molecularly imprinted polymer is presented as a carbon fiber microelectrode coating for determining the presence of paracetamol. The polymeric film was obtained by electrocopolymerization of o-phenylenediamine and aniline in the presence of the template molecule, through the use of cyclic voltammetry. After removing the template, the signals of the microsensor were converted into physical ones by a voltammetric transductor using square wave voltammetry. Various parameters influencing the electropolymerization and voltammetric determination processes were examined and optimized. The response of the imprinted microsensor to paracetamol was linearly proportional to its concentration over the range 6.5 x 10(-6) to 2.0 x 10(-3) mol l(-1), with good stability and reproducibility (RSD, <5.6%). The detection limit was 1.5 mu M. Under the experimental conditions used the voltammetric microsensor was able to differentiate between paracetamol and other closely structurally-related compounds present in biological fluids, such as certain catecholamines.
引用
收藏
页码:1012 / 1018
页数:7
相关论文
共 29 条
[1]   Molecular imprinting for drug bioanalysis - A review on the application of imprinted polymers to solid-phase extraction and binding assay [J].
Andersson, LI .
JOURNAL OF CHROMATOGRAPHY B, 2000, 739 (01) :163-173
[2]   Electrochemical sensors based on molecularly imprinted polymers [J].
Blanco-López, MC ;
Lobo-Castañón, MJ ;
Miranda-Ordieres, AJ ;
Tuñón-Blanco, P .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2004, 23 (01) :36-48
[3]   Voltammetric response of diclofenac-molecularly imprinted film modified carbon electrodes [J].
Blanco-López, MC ;
Lobo-Castañón, MJ ;
Miranda-Ordieres, AJ ;
Tuñón-Blanco, P .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (02) :257-261
[4]   Voltammetric sensor for vanillylmandelic acid based on molecularly imprinted polymer-modified electrodes [J].
Blanco-López, MC ;
Lobo-Castañón, MJ ;
Miranda-Ordieres, AJ ;
Tuñón-Blanco, P .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (04) :353-362
[5]   Evaluation of methods aimed at complete removal of template from molecularly imprinted polymers [J].
Ellwanger, A ;
Berggren, C ;
Bayoudh, S ;
Crecenzi, C ;
Karlsson, L ;
Owens, PK ;
Ensing, K ;
Cormack, P ;
Sherrington, D ;
Sellergren, B .
ANALYST, 2001, 126 (06) :784-792
[6]   Selective trace enrichment of chlorotriazine pesticides from natural waters and sediment samples using terbuthylazine molecularly imprinted polymers [J].
Ferrer, I ;
Lanza, F ;
Tolokan, A ;
Horvath, V ;
Sellergren, B ;
Horvai, G ;
Barceló, D .
ANALYTICAL CHEMISTRY, 2000, 72 (16) :3934-3941
[7]  
GARCIA RM, 1990, QUIM ANAL, V9, P189, DOI DOI 10.21577/0100-4042.20170080
[8]  
Guo HS, 2003, CHINESE J CHEM, V21, P1624
[9]  
Gutierrez-Fernandez S, 2001, ELECTROANAL, V13, P1399, DOI 10.1002/1521-4109(200111)13:17<1399::AID-ELAN1399>3.0.CO
[10]  
2-W