The spatial variability in concentrations of a traffic-related pollutant in two street canyons in York, UK - Part I: The influence of background winds

被引:47
作者
Boddy, JWD
Smalley, RJ
Dixon, NS
Tate, JE
Tomlin, AS [1 ]
机构
[1] Univ Leeds, Energy & resources Res Inst, Leeds LS2 9JT, W Yorkshire, England
[2] Univ Leeds, Inst Transport Studies, Leeds LS2 9JT, W Yorkshire, England
关键词
pollutant dispersion; vortex; wind flow; urban;
D O I
10.1016/j.atmosenv.2005.01.043
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The influence of background wind flow on the dispersion of carbon monoxide (CO) was investigated over a one-month period in two street canyons of differing geometry in the city of York, UK. Electrochemical sensors were used to measure CO concentrations at various heights and locations along each canyon. Six ultrasonic anemometers were used to measure the airflow and turbulence within one of the canyons. A seventh anemometer measured the above-roof (or background) winds at approximately twice the street building height. Bi-directional traffic flow was measured in each street using the Split, Cycle and Offset Optimisation Technique (SCOOT) system. The investigation indicates that differences in the street geometry and the background winds result in contrasting in-canyon wind flows and dispersion characteristics. Whilst there is evidence of a single cross canyon vortex in one street canyon for certain background wind directions, there are also a number of three-dimensional (313) flow structures formed in the canyon due to the influence of flow channelling, both within the canyon and from adjoining side streets. For background winds with a strong perpendicular component relative to the canyon axes, the mean CO concentrations on the leeward side of the street canyons were on average, a factor of two greater than on the windward side. This feature can be attributed to the formation of vertical and horizontal vortices. However, when the concentrations were normalised by the background wind speed and total traffic flow, a three-fold difference exists between the windward and leeward sides of the street canyon. Evidence of flow channelling and helical flow regimes was also detected for background flows with a component parallel to the canyon axes. The difference in mean CO concentrations between the two street canyons was approximately two-fold, with the highest mean concentrations in the narrower canyon, which has a smaller cross-sectional area. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3147 / 3161
页数:15
相关论文
共 41 条
[1]  
Baik JJ, 1999, J APPL METEOROL, V38, P1576, DOI 10.1175/1520-0450(1999)038<1576:ANSOFA>2.0.CO
[2]  
2
[3]  
Berkowicz R, 2002, URBAN AIR QUALITY - RECENT ADVANCES, PROCEEDINGS, P311
[4]  
BODDY JWD, 2005, IN PRESS ATMOSPHER 2, DOI DOI 10.1016/J.ATMOSENV.2005.01.044
[5]   Spatial distribution of urban pollution: Civilizing urban traffic [J].
Croxford, B ;
Penn, A ;
Hillier, B .
SCIENCE OF THE TOTAL ENVIRONMENT, 1996, 189 :3-9
[6]   Siting considerations for urban pollution monitors [J].
Croxford, B ;
Penn, A .
ATMOSPHERIC ENVIRONMENT, 1998, 32 (06) :1049-1057
[7]   The next generation of integrated air quality modeling: EPA's Models-3 [J].
Dennis, RL ;
Byun, DW ;
Novak, JH ;
Galluppi, KJ ;
Coats, CJ ;
Vouk, MA .
ATMOSPHERIC ENVIRONMENT, 1996, 30 (12) :1925-1938
[8]   MEASUREMENTS OF WIND VELOCITIES IN A STREET CANYON [J].
DEPAUL, FT ;
SHEIH, CM .
ATMOSPHERIC ENVIRONMENT, 1986, 20 (03) :455-459
[9]   ANALYSIS AND INTERPRETATION OF AIR-QUALITY DATA FROM AN URBAN ROADSIDE LOCATION IN CENTRAL LONDON OVER THE PERIOD FROM JULY 1991 TO JULY 1992 [J].
DERWENT, RG ;
MIDDLETON, DR ;
FIELD, RA ;
GOLDSTONE, ME ;
LESTER, JN ;
PERRY, R .
ATMOSPHERIC ENVIRONMENT, 1995, 29 (08) :923-946
[10]  
DIXON NS, 2004, P 13 INT SCI S TRANS, P89