Comparison of fine-needle aspiration cytology and core biopsy for diagnosis of breast cancer

被引:28
作者
Sun, W [1 ]
Li, AL [1 ]
Abreo, F [1 ]
Turbat-Herrera, E [1 ]
Grafton, WD [1 ]
机构
[1] Louisiana State Univ, Hlth Sci Ctr, Dept Pathol, Shreveport, LA 71105 USA
关键词
breast cancer diagnosis; breast FNA cytology; breast core biopsy;
D O I
10.1002/dc.1092
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Both fine-needle aspiration (FNA) cytology and core biopsy are useful in the diagnosis of breast cancel: In order to compare the sensitivities of these procedures, we reviewed 209 patients with breast cancer who had either FNA, core biopsy, or both, and also either mastectomy or lumpectomy. Sensitivities for FNA and core biopsies for diagnosing breast cancer were calculated and compared. Sensitivity for FNA or core biopsies interpreted as either atypical or malignant was 93.8% for FNA and 90.1% for core biopsy (P > 0.05). Sensitivity for. FNA or core biopsies interpreted as malignant was 65.4% for FNA and 88.7% for core biopsy (P < 0.0001). Sensitivities of FNA interpreted as either atypical or malignant were 92.4% for FNA performed by pathologists and 100% for FNA by nonpathologists (P > 0.05). Sensitivities of FNA interpreted as malignant were 75.8% for FNA by pathologists and 20.0% for FNA by nonpathologists (P < 0.00001). Both FNA and core biopsies are sensitive procedures Sol the detection of breast cancer. There M,as no significant difference between. sensitivity of FNA and col e biopsies interpreted as either atypia or malignancy, although the sensitivity of core biopsies interpreted as unequivocal malignancy was greater than that of FNA. FNAs performed by pathologists were more sensitive than FNAs performed by nonpathologists in making an unequivocal diagnosis of breast cancer (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:421 / 425
页数:5
相关论文
共 36 条
[1]  
ABATI A, 1997, AM J SURG, V174, P371
[2]   STEREOTACTIC FINE-NEEDLE BIOPSY IN 2594 MAMMOGRAPHICALLY DETECTED NON-PALPABLE LESIONS [J].
AZAVEDO, E ;
SVANE, G ;
AUER, G .
LANCET, 1989, 1 (8646) :1033-1036
[3]  
Ballo MS, 1996, CANCER, V78, P773
[4]  
Bernstein JR, 1996, SEMIN SURG ONCOL, V12, P290, DOI 10.1002/(SICI)1098-2388(199609/10)12:5<290::AID-SSU3>3.3.CO
[5]  
2-2
[6]   RANDOMIZED COMPARISON OF FINE-NEEDLE ASPIRATION CYTOLOGY AND BIOPTY-CUT NEEDLE-BIOPSY AFTER UNSATISFACTORY INITIAL CYTOLOGY OF DISCRETE BREAST-LESIONS [J].
CARTY, NJ ;
RAVICHANDRAN, D ;
CARTER, C ;
MUDAN, S ;
ROYLE, GT ;
TAYLOR, I .
BRITISH JOURNAL OF SURGERY, 1994, 81 (09) :1313-1314
[7]  
Chilcote WA, 1997, CLEV CLIN J MED, V64, P550
[8]  
CUSICK JD, 1990, SURG GYNECOL OBSTET, V170, P407
[9]   Histological precision of stereotactic core biopsy in diagnosis of malignant and premalignant breast lesions [J].
Dahlstrom, JE ;
Sutton, S ;
Jain, S .
HISTOPATHOLOGY, 1996, 28 (06) :537-541
[10]  
Dershaw DD, 1998, ONCOLOGY-NY, V12, P907