A compact fibre-based fluorescence sensor

被引:14
作者
Ahmad, M
Chang, KP
King, TA
Hench, LL
机构
[1] Univ London Imperial Coll Sci Technol & Med, Dept Mat, London SW7 2BP, England
[2] Univ Manchester, Dept Phys & Astron, Lasers Photon Res Grp, Schuster Lab, Manchester M13 9PL, Lancs, England
关键词
fluorescence sensors; fibres; lasers; laser dye; biological and chemical agents; leaky fibre and cells;
D O I
10.1016/j.sna.2004.09.007
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A compact sensor consisting of two positive guiding fibres and one negative non-guiding fibre has been developed with large sensitivity for detection of fluorescence emitted from a laser dye. The positive fibre is used to deliver laser light to the negative fibre. The negative fibre acts as a sensing element, the pump light leaks into its surrounding which excites the laser dye molecules embedded in an index matched liquid coated onto the core of the negative fibre. The fluorescence is guided by another positive fibre attached to the distal end of the negative fibre and detected by a CCD camera. The response of the sensor with various fibre diameters and sensing lengths as a function of laser dye concentration has been determined. The sensor is capable of measuring 50 pg/ml of laser dye (rhodamine 6G). (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:84 / 89
页数:6
相关论文
共 23 条
[1]   Performance and photostability of xanthene and pyrromethene laser dyes in sol-gel phases [J].
Ahmad, M ;
King, TA ;
Ko, DK ;
Cha, BH ;
Lee, J .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2002, 35 (13) :1473-1476
[2]  
AHMAD M, IN PRESS BIOSENS BIO
[3]  
AXELROD D, 1990, TOTAL INTERNAL REFLE
[4]   Effect of selected environmental and physico-chemical factors on bacterial cytoplasmic membranes [J].
Denich, TJ ;
Beaudette, LA ;
Lee, H ;
Trevors, JT .
JOURNAL OF MICROBIOLOGICAL METHODS, 2003, 52 (02) :149-182
[5]   Tapered single-mode optical fiber evanescent coupling [J].
Fielding, AJ ;
Davis, CC .
IEEE PHOTONICS TECHNOLOGY LETTERS, 2002, 14 (01) :53-55
[6]   EFFECT OF NUMERICAL APERTURE ON SIGNAL LEVEL IN CYLINDRICAL WAVE-GUIDE EVANESCENT FLUOROSENSORS [J].
GLASS, TR ;
LACKIE, S ;
HIRSCHFELD, T .
APPLIED OPTICS, 1987, 26 (11) :2181-2187
[7]   FLUOROMETER AND TAPERED FIBER OPTIC PROBES FOR SENSING IN THE EVANESCENT WAVE [J].
GOLDEN, JP ;
SHRIVERLAKE, LC ;
ANDERSON, GP ;
THOMPSON, RB ;
LIGLER, FS .
OPTICAL ENGINEERING, 1992, 31 (07) :1458-1462
[8]   AN EVANESCENT-WAVE BIOSENSOR .2. FLUORESCENT SIGNAL ACQUISITION FROM TAPERED FIBER OPTIC PROBES [J].
GOLDEN, JP ;
ANDERSON, GP ;
RABBANY, SY ;
LIGLER, FS .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1994, 41 (06) :585-591
[9]   The single mode tapered optical fibre loop immunosensor [J].
Hale, ZM ;
Payne, FP ;
Marks, RS ;
Lowe, CR ;
Levine, MM .
BIOSENSORS & BIOELECTRONICS, 1996, 11 (1-2) :137-148
[10]  
HENCH LL, 1998, SOL GEL SILICA PROPE, P72