Planar strip array (PSA) for MRI

被引:64
作者
Lee, RF
Westgate, CR
Weiss, RG
Newman, DC
Bottomley, PA
机构
[1] Johns Hopkins Univ, Dept Radiol, Div MR Res, Baltimore, MD USA
[2] Johns Hopkins Univ, Dept Elect & Comp Engn, Baltimore, MD USA
[3] Johns Hopkins Univ, Dept Med, Div Cardiol, Baltimore, MD USA
[4] Johns Hopkins Univ, Whiting Sch Engn, Dorsey Ctr, Baltimore, MD USA
关键词
MRI detector; phased array; planar strip array (PSA); sensitivity encoding; SMASH; SENSE; ASP; standing wave detector; surface coil;
D O I
10.1002/mrm.1090
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Parallel, spatial-encoded MRI requires a large number of independent detectors that simultaneously acquire signals. The loop structure and mutual coupling in conventional phased arrays limit the number of coils and therefore the potential reduction in minimum scan time achievable by parallel MRI tchniques. A new near-field MRI detector array, the planar strip array (PSA), is presented that eliminates the coupling problems and can be extended to a very large number of detectors and high MRI frequencies. Its basic structure is an array of parallel microstrips with a high permittivity substrate and overlay. The electromagnetic (EM) wavelength can be adjusted with the permittivity, and the strip lengths tuned to a preselected fraction of the wavelength of the MRI frequency. EM wave analysis and measurements on a prototype four-element PSA reveal that the coupling between the strips vanishes when the strip length is either an integer times a quarter wavelength for a standing-wave PSA, or a half wavelength for a travelling-wave PSA, independent of the spacing between the strips. The analysis, as well as phantom and human MRI experiments performed by conventional and parallel-encoded MRI with the PSA at 1.5 T, show that the decoupled strips produce a relatively high-quality factor and signal-to-noise ratio, provided that the strips are properly terminated, tuned, and matched or coupled to the preamplifiers. Magn Reson Med 45:673-683, 2001. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:673 / 683
页数:11
相关论文
共 31 条
[1]   PARAMETERS OF MICROSTRIP TRANSMISSION LINES AND OF COUPLED PAIRS OF MICROSTRIP LINES [J].
BRYANT, TG ;
WEISS, JA .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1968, MT16 (12) :1021-&
[2]  
Chen CN, 1989, BIOMEDICAL MAGNETIC
[3]  
Cohn S.B., 1955, Microwave Theory and Techniques, IRE Transactions on, V3, P29
[4]   AN ANALYTICAL MODEL FOR THE DESIGN OF RF RESONATORS FOR MR BODY IMAGING [J].
FOO, TKF ;
HAYES, CE ;
KANG, YW .
MAGNETIC RESONANCE IN MEDICINE, 1991, 21 (02) :165-177
[5]   AN EFFICIENT, HIGHLY HOMOGENEOUS RADIOFREQUENCY COIL FOR WHOLE-BODY NMR IMAGING AT 1.5-T [J].
HAYES, CE ;
EDELSTEIN, WA ;
SCHENCK, JF ;
MUELLER, OM ;
EASH, M .
JOURNAL OF MAGNETIC RESONANCE, 1985, 63 (03) :622-628
[6]  
HAYES CE, 1988, Patent No. 4783641
[7]  
HELSZAJN J, 1994, MICROWAVE PLANAR PAS
[8]  
Jakob PM, 1998, MAGN RESON MATER PHY, V7, P42
[9]  
Jones E.M. T., 1956, MICROWAVE THEORY TEC, V4, P75
[10]   A DECOUPLED COIL DETECTOR ARRAY FOR FAST IMAGE ACQUISITION IN MAGNETIC-RESONANCE-IMAGING [J].
KWIAT, D ;
EINAV, S ;
NAVON, G .
MEDICAL PHYSICS, 1991, 18 (02) :251-265