Evaluation of fluorescent monochloro-s-triazine reagent for amino acid analysis

被引:4
作者
Brückner, H [1 ]
Wachsmann, M [1 ]
机构
[1] Univ Giessen, Interdisciplinary Res Ctr, Inst Nutr Sci, Dept Food Sci, D-35392 Giessen, Germany
关键词
column liquid chromatography; amino acid analysis; pre-column derivatization; fluorescence labelling; cyanuric chloride;
D O I
10.1007/BF02492096
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The fluorescent reagent 2-chloro-4-methoxy-6-(4-methoxy-1-naphthyl)-[1,3,5]triazine (CMMNT) has been synthesized and used for derivatization of mixtures of a-amino acids. The derivatives were resolved on a Nucleosil(R) C-18 column using a linear gradient of 0.1% aqueous trifluoroacetic acid in acetonitrile and detected by their fluorescence at 415 nm using an excitation of 336 rim. Using a standard the linearity was determined from 0.13 - 26 pmol per amino acid derivative and the detection limit was 6.6 x 10(-2) pmol at a signal-to-noise ratio of 3.5. This approach was used for quantitative, amino acid analysis of total hydrolysates of synthetic peptides and for fluorescence labelling of casein.
引用
收藏
页码:S143 / S146
页数:4
相关论文
共 26 条
[1]   IMMUNOFLUORESCENCE USING DICHLOROTRIAZINYLAMINOFLUORESCEIN (DTAF) .1. PREPARATION AND FRACTIONATION OF LABELED IGG [J].
BLAKESLEE, D ;
BAINES, MG .
JOURNAL OF IMMUNOLOGICAL METHODS, 1976, 13 (3-4) :305-320
[2]   Liquid chromatographic separation of amino acid enantiomers on a silica-bonded chiral s-triazine column [J].
Bruckner, H ;
Wachsmann, M .
JOURNAL OF CHROMATOGRAPHY A, 1996, 728 (1-2) :447-454
[3]   USE OF CHIRAL MONOHALO-S-TRIAZINE REAGENTS FOR THE LIQUID-CHROMATOGRAPHIC RESOLUTION OF DL-AMINO ACIDS [J].
BRUCKNER, H ;
STRECKER, B .
JOURNAL OF CHROMATOGRAPHY, 1992, 627 (1-2) :97-105
[4]   USE OF CHROMOGENIC AND FLUORESCENT OXYCARBONYL CHLORIDES AS REAGENTS FOR AMINO-ACID-ANALYSIS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BRUCKNER, H ;
LUPKE, M .
JOURNAL OF CHROMATOGRAPHY A, 1995, 697 (1-2) :295-307
[5]   1-ETHOXY-4-(DICHLORO-S-TRIAZINYL)NAPHTHALENE - FLUORESCENT REAGENT FOR CORTICOSTEROIDS [J].
CHAYEN, R ;
GOULD, S ;
HARELL, A ;
STEAD, CV .
ANALYTICAL BIOCHEMISTRY, 1971, 39 (02) :533-&
[6]   SYNTHESIS OF A FLUORESCENT DERIVATIZING REAGENT, 6-AMINOQUINOLYL-N-HYDROXYSUCCINIMIDYL CARBAMATE, AND ITS APPLICATION FOR THE ANALYSIS OF HYDROLYSATE AMINO-ACIDS VIA HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
COHEN, SA ;
MICHAUD, DP .
ANALYTICAL BIOCHEMISTRY, 1993, 211 (02) :279-287
[7]   2-(9-ANTHRYL)ETHYL CHLOROFORMATE - A PRECOLUMN DERIVATIZING REAGENT FOR POLYAMINES DETERMINED BY LIQUID-CHROMATOGRAPHY AND FLUORESCENCE DETECTION [J].
FAULKNER, AJ ;
VEENING, H ;
BECKER, HD .
ANALYTICAL CHEMISTRY, 1991, 63 (03) :292-296
[8]   3-(dichloro-1,3,5-triazinyl)benz[f]isoindolo[1,2-b][1,3]thiazolidine as a derivatization reagent for bisphenols in high-performance liquid chromatography with argon laser-induced fluorescence detection [J].
Fujino, H ;
Yoshida, H ;
Nohta, H ;
Yamaguchi, M .
ANALYTICAL SCIENCES, 2000, 16 (09) :975-977
[9]  
Godel H., 1992, LC GC INT, V5, P44
[10]   FULLY AUTOMATED AMINO-ACID-ANALYSIS FOR PROTEIN AND PEPTIDE HYDROLYSATES BY PRECOLUMN DERIVATIZATION WITH 9-FLUORENYL METHYLCHLOROFORMATE AND 1-AMINOADAMANTANE [J].
GUSTAVSSON, B ;
BETNER, I .
JOURNAL OF CHROMATOGRAPHY, 1990, 507 :67-77