Selecting the right fluorophores and flow cytometer for fluorescence resonance energy transfer measurements

被引:31
作者
Horváth, G
Petrás, M
Szentesi, G
Fabián, A
Park, JW
Vereb, G
Szöllosi, J
机构
[1] Univ Debrecen, Fac Med, Med & Hlth Sci Ctr, Dept Biochem & Cell Biol, H-4012 Debrecen, Hungary
[2] Univ Debrecen, Hungarian Acad Sci, Med & Hlth Sci Ctr, Res Ctr Mol Med,Cell Biophys Res Grp, H-4012 Debrecen, Hungary
[3] Univ Calif San Francisco, Dept Hematol Oncol, San Francisco, CA 94143 USA
关键词
fluorescence resonance energy transfer; flow cytometry; donor-acceptor pair;
D O I
10.1002/cyto.a.20142
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Fluorescence resonance energy transfer applied in flow cytometry (FCET) is an excellent toot for determining supramolecular organization of biomolecules at the cell surface or inside the cell. Availability of new fluorophores and cytometers requires the establishment of fluorophore dye pairs most suitable for FCET measurements. Methods: A gastric tumor cell line (N87) was labeled for major histocompatibility complex class I heavy chain and beta 2-microglobulin with antibodies conjugated with fluorescein- and indocarbocyanine-like fluorophores and analyzed in FCET measurements on a cell-by-cell basis using three flow cytometers: FACSCalibur, FACSDiVa, and FACSArray. Results: Normalized fluorescence intensity values were measured and normalized energy transfer efficiencies, spectral overlap integrals, and crucial dye- and instrument-dependent parameters were calculated for all matching pairs of seven fluorophores on the three commercial cytometers. The most crucial parameter in determining the applicability of the donor-acceptor pairs was the normalized fluorescence intensity and the least important one was the spectral overlap. Conclusions: On the basis of available laser lines, the optimal dye pair for all three cytometers is the Alexa546-Alexa647 pair, which produces high energy transfer efficiency values and has the best spectral characteristics with regard to laser excitation, detection of emission, and spectral overlap. (c) 2005 Wiley-Liss, Inc.
引用
收藏
页码:148 / 157
页数:10
相关论文
共 48 条
[1]   Molecular modeling of nearly full-length ErbB2 receptor [J].
Bagossi, P ;
Horváth, G ;
Vereb, G ;
Szöllösi, J ;
Tözsér, J .
BIOPHYSICAL JOURNAL, 2005, 88 (02) :1354-1363
[2]   Microspectroscopic imaging tracks the intracellular processing of a signal transduction protein: Fluorescent-labeled protein kinase C beta I [J].
Bastiaens, PIH ;
Jovin, TM .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1996, 93 (16) :8407-8412
[3]   Use of phycoerythrin and allophycocyanin for fluorescence resonance energy transfer analyzed by flow cytometry: Advantages and limitations [J].
Batard, P ;
Szollosi, J ;
Luescher, I ;
Cerottini, JC ;
MacDonald, R ;
Romero, P .
CYTOMETRY, 2002, 48 (02) :97-105
[4]  
Brockhoff G, 2001, CYTOMETRY, V44, P338, DOI 10.1002/1097-0320(20010801)44:4<338::AID-CYTO1125>3.0.CO
[5]  
2-V
[6]   Semiconductor nanocrystals as fluorescent biological labels [J].
Bruchez, M ;
Moronne, M ;
Gin, P ;
Weiss, S ;
Alivisatos, AP .
SCIENCE, 1998, 281 (5385) :2013-2016
[7]  
Chan FKM, 2001, CYTOMETRY, V44, P361, DOI 10.1002/1097-0320(20010801)44:4<361::AID-CYTO1128>3.0.CO
[8]  
2-3
[9]   ORIENTATIONAL FREEDOM OF MOLECULAR PROBES - ORIENTATION FACTOR IN INTRA-MOLECULAR ENERGY-TRANSFER [J].
DALE, RE ;
EISINGER, J ;
BLUMBERG, WE .
BIOPHYSICAL JOURNAL, 1979, 26 (02) :161-193
[10]  
Damjanovich S, 1998, CYTOMETRY, V33, P225, DOI 10.1002/(SICI)1097-0320(19981001)33:2<225::AID-CYTO18>3.0.CO