Measuring mechanical properties of the vastus lateralis tendon-aponeurosis complex in vivo by ultrasound imaging

被引:54
作者
Bojsen-Moller, J [1 ]
Hansen, P [1 ]
Aagaard, P [1 ]
Kjær, M [1 ]
Magnusson, SP [1 ]
机构
[1] Univ Copenhagen, Bispebjerg Hosp, Sports Med Res Unit, Team Denmark Test Ctr, DK-2400 Copenhagen NV, Denmark
关键词
connective tissue mechanical properties; joint rotation correction; ultrasound;
D O I
10.1034/j.1600-0838.2003.00301.x
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
The mechanical properties of the human vastus lateralis (VL) tendon-aponeurosis complex were investigated in eight male subjects. Knee extensor force, knee joint angle, and corresponding longitudinal VL aponeurosis displacement were monitored synchronously during graded (10-s) maximal isometric knee extension contractions. Displacement observed during isometric conditions may be regarded as an expression of deformation in the tissues distal to the measurement site. Furthermore, aponeurosis displacement was measured during passive knee extension (90-75degrees), and used to correct displacement values obtained during active contraction for joint angular motion. The passive trial yielded a highly linear relationship between aponeurosis displacement and joint angular motion (r(2) = 0.998 +/- 0.002) with a mean correction factor of 0.41 +/- 0.10 mm/degree. Maximal knee extensor force was 5834 +/- 1341 N with a corresponding VL aponeurosis displacement of 12.7 +/- 2.5 mm, while correcting for joint angular motion reduced maximal displacement similar to9% (to 11.6 +/- 2.5 mm, P < 0.005) (data presented as means +/- SD). Two separate graded contraction trials were performed, and no between-trial differences were observed in either maximal force or maximal displacement. Between trial coefficient of determination and CV for maximal force and maximal displacement were r(2) = 0.97, CV = 2.9% and r(2) = 0.92, CV = 4.6%, respectively, indicating intra-day reproducibility of measurements. These data demonstrate that when applying the newly established ultrasound-based method of investigating quadriceps connective tissue mechanical properties, maximal isometric contraction is inevitably associated with some joint angular motion that significantly influences the calculations.
引用
收藏
页码:259 / 265
页数:7
相关论文
共 21 条
[1]  
ALEXANDER RM, 1991, J EXP BIOL, V160, P55
[2]  
Biewener A A, 2000, Exerc Sport Sci Rev, V28, P99
[3]  
Bouguet Jean-Yves., 2001, PYRAMIDAL IMPLEMENTA
[4]   ADAPTATIONS IN COACTIVATION AFTER ISOMETRIC RESISTANCE TRAINING [J].
CAROLAN, B ;
CAFARELLI, E .
JOURNAL OF APPLIED PHYSIOLOGY, 1992, 73 (03) :911-917
[5]   SHORTENING OF MUSCLE-FIBERS DURING STRETCH OF THE ACTIVE CAT MEDIAL GASTROCNEMIUS-MUSCLE - THE ROLE OF TENDON COMPLIANCE [J].
GRIFFITHS, RI .
JOURNAL OF PHYSIOLOGY-LONDON, 1991, 436 :219-236
[6]   Interaction between series compliance and sarcomere kinetics determines internal sarcomere shortening during fixed-end contraction [J].
Kawakami, Y ;
Lieber, RL .
JOURNAL OF BIOMECHANICS, 2000, 33 (10) :1249-1255
[7]   Influence of elastic properties of tendon structures on jump performance in humans [J].
Kubo, K ;
Kawakami, Y ;
Fukunaga, T .
JOURNAL OF APPLIED PHYSIOLOGY, 1999, 87 (06) :2090-2096
[8]  
Kubo K, 2000, ACTA PHYSIOL SCAND, V168, P327
[9]   Influences of repetitive muscle contractions with different modes on tendon elasticity in vivo [J].
Kubo, K ;
Kanehisa, H ;
Kawakami, Y ;
Fukunaga, T .
JOURNAL OF APPLIED PHYSIOLOGY, 2001, 91 (01) :277-282
[10]   Effects of different duration isometric contractions on tendon elasticity in human quadriceps muscles [J].
Kubo, K ;
Kanehisa, H ;
Fukunaga, T .
JOURNAL OF PHYSIOLOGY-LONDON, 2001, 536 (02) :649-655