On rotational ambiguity in parallel factor analysis

被引:15
作者
Abdollahi, H. [1 ]
Sajjadi, S. M. [1 ]
机构
[1] Inst Adv Studies Basic Sci, Fac Chem, Zanjan 45195159, Iran
关键词
Rotational ambiguity; PARAFAC; Uniqueness; Rank deficiency; MODELING CURVE RESOLUTION; SPECTROPHOTOMETRIC DATA; 2ND-ORDER CALIBRATION; FEASIBLE SOLUTIONS; BAND BOUNDARIES; COMPONENTS; EXTENSION; MIXTURES; RANK; SPECTRA;
D O I
10.1016/j.chemolab.2010.06.010
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Although, in many cases parallel factor analysis (PARAFAC) resolves the trilinear data arrays to the true physical factors that form the data, i.e., unique solution can be found, the algorithm does not always converge to chemically meaningful solutions. Kiers and Smilde [J. Chemom. 1995; 9: 179-195] rigorously proved that unique decomposition does not hold in cases with 'rank overlap'. They showed when PARAFAC is applied on a three-way data array which has rank overlap in one of its loading modes: the solution obtained is not unique and at best cannot be easily compared with the underlying physical factors owing to a rotational ambiguity. An aspect which is significantly less documented in the previous publications is the reliable detection of rotational ambiguities in multi-way methods. A few reported methods are based on bilinear models for calculating the feasible bands of three-way data. In this paper we propose a method to calculate feasible bands of resolved profiles of components in three-way methods and visualize the rotational ambiguity in three-way data in the results of the three-way methods. Most of discussion is in the PARAFAC algorithm. The principle behind the algorithm is described in detail and tested for simulated data set. Completely general and exhaustive results are presented for the two-component cases. In particular, the effect of the noise is investigated and a comparison is made between feasible solutions obtained from PARAFAC and matrix-augmented with trilinearity. It is shown that the results obtained from both methods are identical. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:144 / 151
页数:8
相关论文
共 40 条
[1]   Evaluation of variation matrix arrays by parallel factor analysis [J].
Abdollahi, Hamid ;
Sajjadi, S. Maryam .
JOURNAL OF CHEMOMETRICS, 2009, 23 (3-4) :139-148
[2]   Calculation and Meaning of Feasible Band Boundaries in Multivariate Curve Resolution of a Two-Component System [J].
Abdollahi, Hamid ;
Maeder, Marcel ;
Tauler, Romai .
ANALYTICAL CHEMISTRY, 2009, 81 (06) :2115-2122
[3]  
[Anonymous], 1989, Multiway data analysis
[4]   AN EXTENSION OF THE MULTIVARIATE COMPONENT-RESOLUTION METHOD TO 3 COMPONENTS [J].
BORGEN, OS ;
KOWALSKI, BR .
ANALYTICA CHIMICA ACTA, 1985, 174 (AUG) :1-26
[5]   PARAFAC. Tutorial and applications [J].
Bro, R .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1997, 38 (02) :149-171
[6]   Exploratory study of sugar production using fluorescence spectroscopy and multi-way analysis [J].
Bro, R .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1999, 46 (02) :133-147
[7]   Modeling multi-way data with linearly dependent loadings [J].
Bro, Rasmus ;
Harshman, Richard A. ;
Sidiropoulos, Nicholas D. ;
Lundy, Margaret E. .
JOURNAL OF CHEMOMETRICS, 2009, 23 (7-8) :324-340
[8]   ANALYSIS OF INDIVIDUAL DIFFERENCES IN MULTIDIMENSIONAL SCALING VIA AN N-WAY GENERALIZATION OF ECKART-YOUNG DECOMPOSITION [J].
CARROLL, JD ;
CHANG, JJ .
PSYCHOMETRIKA, 1970, 35 (03) :283-&
[9]   Assessment of new constraints applied to the alternating least squares method [J].
deJuan, A ;
VanderHeyden, Y ;
Tauler, R ;
Massart, DL .
ANALYTICA CHIMICA ACTA, 1997, 346 (03) :307-318
[10]   Two Multivariate strategies applied to three-way kinetic spectrophotometric data for the determination of mixtures of the pesticides carbaryl and chlorpyrifos [J].
Espinosa-Mansilla, A ;
de la Peña, AM ;
Goicoechea, TC ;
Olivieri, AC .
APPLIED SPECTROSCOPY, 2004, 58 (01) :83-90