Comparing different control strategies for indoor thermal comfort aimed at the evaluation of the energy cost of quality of building

被引:51
作者
Calvino, Francesco [1 ]
La Gennusa, Maria [1 ]
Morale, Massimo [1 ]
Rizzo, Gianfranco [1 ]
Scaccianoce, Gianluca [1 ]
机构
[1] Univ Palermo, Dipartimento Ric Energet Ambientali DREAM, I-90128 Palermo, Italy
关键词
Fuzzy logic; Indoor thermal comfort; Energy saving; HVAC system controller; PID controller; SYSTEM OPTIMIZATION; FUZZY CONTROLLER; HVAC; DESIGN; MANAGEMENT;
D O I
10.1016/j.applthermaleng.2010.06.008
中图分类号
O414.1 [热力学];
学科分类号
摘要
The rapid improvement in the standard of living requires more detailed and sophisticated methods of evaluating comfort conditions. But, maintaining thermal comfort conditions in confined environments may require complex regulation procedures and the proper management of heating, ventilating and air conditioning (HVAC) systems. In turn, the requirements for indoor thermal comfort do not necessarily coincide with those of energy saving purposes, which in the last years are becoming a crucial issue owing to the enactment of the European Energy Performance of Buildings Directive (EPBD). The aim of this work is to compare different indoor control thermal comfort strategies in view of the evaluation of the energy cost of quality in buildings. In particular, a new PID-fuzzy controller is presented and compared with a classic ON OFF controller. The performances of the two controllers are quantified and compared by means of two cost functions that are based on the quadratic forms of the overall energy required by the thermal fluid and of the deviation from the preferred set point of the predicted mean vote (PMV). It is found that the application of the PID-fuzzy controller results in lower costs of energy input and lower deviation from set point of PMV. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2386 / 2395
页数:10
相关论文
共 26 条
[1]  
[Anonymous], 2007, ASHRAE HDB HVAC APPL
[2]  
[Anonymous], 2005, Ergonomics of the thermal environment _ Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria
[3]  
[Anonymous], 1998, ISO 7726 ERGONOMICS
[4]  
[Anonymous], 2007, 15251 CEN EN EUR COM
[5]  
[Anonymous], 2004, ANSIASHRAE STANDARD
[6]  
ARDHEALI MM, 2004, ENERGY CONVERSION MA, V45, P1981
[7]  
BECCALI M, 2004, ENCY ENERGY, V6
[8]   The control of indoor thermal comfort conditions: introducing a fuzzy adaptive controller [J].
Calvino, F ;
La Gennusa, M ;
Rizzo, G ;
Scaccianoce, G .
ENERGY AND BUILDINGS, 2004, 36 (02) :97-102
[9]  
*CEN, 2003, 4422 CEN EN COMM STA
[10]  
De Dear R., 1998, Build. Eng., V104, P145