Interlaboratory study of a liquid chromatography method for erythromycin: determination of uncertainty

被引:20
作者
Dehouck, P
Heyden, YV
Smeyers-Verbeke, J
Massart, DL
Marini, RD
Chiap, P
Hubert, P
Crommen, J
Van de Wauw, W
De Beer, J
Cox, R
Mathieu, G
Reepmeyer, JC
Voigt, B
Estevenon, O
Nicolas, A
Van Schepdael, A
Adams, E
Hoogmartens, J
机构
[1] Katholieke Univ Leuven, Lab Farmaceut Chem & Anal Geneesmiddelen, B-3000 Louvain, Belgium
[2] Free Univ Brussels, Brussels, Belgium
[3] Univ Liege, Inst Pharm, Dept Pharmaceut Analyt Chem, Liege, Belgium
[4] Wetenschappelijk Inst Volksgezondheid Louis Paste, Brussels, Belgium
[5] Abbott Fermentat Prod, N Chicago, IL USA
[6] Abbott Fermentat Prod, Barcelonata, PR USA
[7] US FDA, Div Pharmaceut Anal, St Louis, MO USA
[8] US Pharmacopeia, Res & Dev Lab, Rockville, MD USA
[9] Univ Henri Poincare, Fac Pharm, Chim Analyt Lab, Nancy, France
关键词
interlaboratory study; uncertainty; reproducibility; validation; erythromycin; ACIDIC AQUEOUS-SOLUTIONS; DECOMPOSITION; SUBSTANCES;
D O I
10.1016/S0021-9673(03)01023-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Erythromycin is a mixture of macrolide antibiotics produced by Saccharopolyspora erythreas during fermentation. A new method for the analysis of erythromycin by liquid chromatography has previously been developed. It makes use of an Astec C-18 polymeric column. After validation in one laboratory, the method was now validated in an interlaboratory study. Validation studies are commonly used to test the fitness of the analytical method prior to its use for routine quality testing. The data derived in the interlaboratory study can be used to make an uncertainty statement as well. The relationship between validation and uncertainty statement is not clear for many analysts and there is a need to show how the existing data, derived during validation, can be used in practice. Eight laboratories participated in this interlaboratory study. The set-up allowed the determination of the repeatability variance, S-r(2) and the between-laboratory variance, S-L(2) Combination of S-r(2) and S-L(2) results in the reproducibility variance S-R(2). It has been shown how these data can be used in future by a single laboratory that wants to make an uncertainty statement concerning the same analysis. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:63 / 74
页数:12
相关论文
共 16 条
[1]   INTERLABORATORY VARIABILITY IN TRACE-ELEMENT ANALYSIS [J].
BOYER, KW ;
HORWITZ, W ;
ALBERT, R .
ANALYTICAL CHEMISTRY, 1985, 57 (02) :454-459
[2]  
Bryskier A.J., 1993, Macrolides: chemistry, pharmacology and clinical uses
[3]   DECOMPOSITION KINETICS OF ERYTHROMYCIN-A IN ACIDIC AQUEOUS-SOLUTIONS [J].
CACHET, T ;
VANDENMOOTER, G ;
HAUCHECORNE, R ;
VINCKIER, C ;
HOOGMARTENS, J .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1989, 55 (01) :59-65
[4]  
Chepkwony HK, 2001, CHROMATOGRAPHIA, V53, P159
[5]  
*COUNC EUR, 2002, EUR PHARM
[6]   Comparison of two LC methods for the analysis of erythromycin [J].
Dehouck, P ;
Roets, E ;
Hoogmartens, J .
CHROMATOGRAPHIA, 2003, 57 (9-10) :671-675
[7]   Determination of uncertainty in analytical measurements from collaborative study results on the analysis of a phenoxymethylpenicillin sample [J].
Dehouck, P ;
Vander Heydon, Y ;
Smeyers-Verbeke, J ;
Massart, DL ;
Crommen, J ;
Hubert, P ;
Marini, RD ;
Smeets, OSNM ;
Decristoforo, G ;
Van de Wauw, W ;
De Beer, J ;
Quaglia, MG ;
Stella, C ;
Veuthey, JL ;
Estevenon, O ;
Van Schepdael, A ;
Roets, E ;
Hoogmartens, J .
ANALYTICA CHIMICA ACTA, 2003, 481 (02) :261-272
[8]  
*EUR CIT GUID, 2000, QUANT UNC AN MEAS
[9]  
*ICH STEER COMM, 1994, ICH HARM TRIP GUID T
[10]  
*ISO IEC, 1994, 57252 ISOIEC