General bounds for electrode mislocation on the EEG inverse problem

被引:24
作者
Beltrachini, L. [1 ]
von Ellenrieder, N. [1 ]
Muravchik, C. H. [1 ]
机构
[1] Univ Nacl La Plata, Fac Ingn, LEICI, Buenos Aires, DF, Argentina
关键词
Cramer-Rao bound; Electrode mislocation; EEG; Inverse problem; DISCRETIZATION; LOCALIZATION; ACCURACY;
D O I
10.1016/j.cmpb.2010.05.008
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We analyze the effect of electrode mislocation on the electroencephalography (EEG) inverse problem using the Cramer-Rao bound (CRB) for single dipolar source parameters. We adopt a realistic head shape model, and solve the forward problem using the Boundary Element Method; the use of the CRB allows us to obtain general results which do not depend on the algorithm used for solving the inverse problem. We consider two possible causes for the electrode mislocation, errors in the measurement of the electrode positions and an imperfect registration between the electrodes and the scalp surfaces. For 120 electrodes placed in the scalp according to the 10-20 standard, and errors on the electrode location with a standard deviation of 5 mm, the lower bound on the standard deviation in the source depth estimation is approximately 1 mm in the worst case. Therefore, we conclude that errors in the electrode location may be tolerated since their effect on the EEG inverse problem are negligible from a practical point of view. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 34 条
[1]  
Bruno P, 2004, P ANN INT IEEE EMBS, V26, P825
[2]   A LINEAR DISCRETIZATION OF THE VOLUME CONDUCTOR BOUNDARY INTEGRAL-EQUATION USING ANALYTICALLY INTEGRATED ELEMENTS [J].
DEMUNCK, JC .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (09) :986-990
[3]   MATHEMATICAL DIPOLES ARE ADEQUATE TO DESCRIBE REALISTIC GENERATORS OF HUMAN-BRAIN ACTIVITY [J].
DEMUNCK, JC ;
VANDIJK, BW ;
SPEKREIJSE, H .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (11) :960-966
[4]   A PRACTICAL METHOD FOR DETERMINING ELECTRODE POSITIONS ON THE HEAD [J].
DEMUNCK, JC ;
VIJN, PCM ;
SPEKREIJSE, H .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1991, 78 (01) :85-87
[5]  
DEUSCHL G, 1999, CLIN NEUROPHYSIOL S, V52
[6]  
Friston K, 2007, STATISTICAL PARAMETRIC MAPPING: THE ANALYSIS OF FUNCTIONAL BRAIN IMAGES, P1
[7]   ON BIOELECTRIC POTENTIALS IN AN INHOMOGENEOUS VOLUME CONDUCTOR [J].
GESELOWI.DB .
BIOPHYSICAL JOURNAL, 1967, 7 (01) :1-&
[8]   The influence of boundary element discretization on the forward and inverse problem in electroencephalography and magnetoencephalography [J].
Haueisen, J ;
Bottner, A ;
Funke, M ;
Brauer, H ;
Nowak, H .
BIOMEDIZINISCHE TECHNIK, 1997, 42 (09) :240-248
[9]   Magnetoencephalography with diversely oriented and multicomponent sensors [J].
Hochwald, B ;
Nehorai, A .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (01) :40-50
[10]   Spatiotemporal EEG/MEG source analysis based on a parametric-noise covariance model [J].
Huizenga, HM ;
de Munck, JC ;
Waldorp, LJ ;
Grasman, RPPP .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (06) :533-539