Comparison of computer-aided detection to double reading of screening mammograms: Review of 231,221 mammograms

被引:109
作者
Gromet, Matthew [1 ]
机构
[1] Breast Imaging Ctr, Charlotte, NC 28203 USA
关键词
breast cancer; computer-aided detection; CAD; double reading; mammography; screening mammography;
D O I
10.2214/AJR.07.2812
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. This study compares the efficacy of single reading with computer-aided detection (CAD) to double reading and also to the first reader (without CAD) in a double-reading program. MATERIALS and METHODS. A review was performed of 231,221 screening mammograms interpreted by experienced mammographers from 2001 through 2005 in a community-based mammography program. In 112,413 (48.6%), mammographers performed the first of two readings. In 118,808 (51.4%), they performed a single reading aided by CAD. RESULTS. For double reading, the first reader's recall rate was 10.2%; sensitivity, 81.4%; positive predictive value, as a percentage of positive screening mammograms resulting in a tissue diagnosis of cancer within 1 year (PPV1), 4.1%; and cancer detection rate, 4.12 per 1,000. After the double-reading process, the final recall rate was 11.9%; sensitivity, 88.0%; PPV1, 3.7%; and cancer detection rate, 4.46 per 1,000. For single-reading with CAD, the recall rate was 10.6%; sensitivity, 90.4%; PPV1, 3.9%; and cancer detection rate, 4.20 per 1,000. Statistically significant results included a lower recall rate with CAD compared with double reading (10.6% vs 11.9%, respectively; p < 0.0001); increased sensitivity with CAD compared with the first reader (90.4% vs 81.4%, p < 0.0001); and increased recall rate with CAD compared with the first reader (10.6% vs 10.2%, p < 0.0001). CONCLUSION. Double reading increased sensitivity with a modest increase in the recall rate compared with single reading. Single reading with CAD, compared with double reading, resulted in a small, but not statistically significant, increase in sensitivity with a lower recall rate. Our results indicate that CAD enhances performance of a single reader, yielding increased sensitivity with only a small increase in recall rate.
引用
收藏
页码:854 / 859
页数:6
相关论文
共 26 条
[1]   THE EFFICACY OF DOUBLE READING MAMMOGRAMS IN BREAST SCREENING [J].
ANDERSON, EDC ;
MUIR, BB ;
WALSH, JS ;
KIRKPATRICK, AE .
CLINICAL RADIOLOGY, 1994, 49 (04) :248-251
[3]   Computer-aided detection with screening mammography in a university hospital setting [J].
Birdwell, RL ;
Bandodkar, P ;
Ikeda, DM .
RADIOLOGY, 2005, 236 (02) :451-457
[4]   A comparison of cancer detection rates achieved by breast cancer screening programmes by number of readers, for one and two view mammography: results from the UK National Health Service breast screening programme [J].
Blanks, RG ;
Wallis, MG ;
Moss, SM .
JOURNAL OF MEDICAL SCREENING, 1998, 5 (04) :195-201
[5]   Improvement in sensitivity of screening mammography with computer-aided detection: A multiinstitutional trial [J].
Brem, RF ;
Baum, J ;
Lechner, M ;
Kaplan, S ;
Souders, S ;
Naul, LG ;
Hoffmeister, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (03) :687-693
[6]  
Burhenne LJW, 2000, RADIOLOGY, V215, P554
[7]  
Burhenne LJW, 2000, RADIOLOGY, V217, P353
[8]  
Castellino Ronald A, 2005, Cancer Imaging, V5, P17, DOI 10.1102/1470-7330.2005.0018
[9]   Impact of computer-aided detection in a regional screening mammography program [J].
Cupples, TE ;
Cunningham, JE ;
Reynolds, JC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (04) :944-950
[10]   Can computer-aided detection with double reading of screening mammograms help decrease the false-negative rate? Initial experience [J].
Destounis, SV ;
DiNitto, P ;
Logan-Young, W ;
Bonaccio, E ;
Zuley, ML ;
Willison, KM .
RADIOLOGY, 2004, 232 (02) :578-584