CMOS neurostimulation ASIC with 100 channels, scaleable output, and bidirectional radio-frequency telemetry

被引:122
作者
Suaning, GJ
Lovell, NH [1 ]
机构
[1] Univ New S Wales, Grad Sch Biomed Sci, Sydney, NSW 2052, Australia
[2] Univ New S Wales, Dept Ophthalmol, Sydney, NSW 2052, Australia
关键词
neurostimulator; retina; telemetry; vision prosthesis; VLSI;
D O I
10.1109/10.909646
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
100-channel neurostimulation circuit comprising a complementary metal oxide semiconductor (CMOS), application-specific integrated circuit (ASIC) has been designed, constructed and tested. The ASIC forms a significant milestone and an integral component of a 100-electrode neurostimulation system being developed by the authors. The system comprises an externally worn transmitter and a body implantable stimulator. The purpose of the system is to communicate both data and power across tissue via radio-frequency (RF) telemetry such that externally programmable, constant current, charge balanced, biphasic stimuli may be delivered to neural tissue at 100 unique sites, An intrinsic reverse telemetry feature of the ASIC has been designed such that information pertaining to the device function, reconstruction of the stimulation voltage waveform, and the measurement of impedance may be obtained through noninvasive means. To compensate for the paucity of data pertaining to the stimulation thresholds necessary in evoking a physiological response, the ASIC has been designed with scaleable current output. The ASIC has been designed primarily as a treatment of degenerative disorders of the retina whereby the 100 channels are to be utilized in the delivery of a pattern of stimuli of varying intensity and or duty cycle to the surviving neural tissue of the retina, However, it is conceivable that other fields of neurostimulation such as cochlear prosthetics and functional electronic stimulation may benefit from the employment of the system.
引用
收藏
页码:248 / 260
页数:13
相关论文
共 29 条
[1]   SENSATIONS PRODUCED BY ELECTRICAL STIMULATION OF VISUAL CORTEX [J].
BRINDLEY, GS ;
LEWIN, WS .
JOURNAL OF PHYSIOLOGY-LONDON, 1968, 196 (02) :479-&
[2]   THE SITE OF ELECTRICAL EXCITATION OF THE HUMAN EYE [J].
BRINDLEY, GS .
JOURNAL OF PHYSIOLOGY-LONDON, 1955, 127 (01) :189-200
[3]  
Brown CJ, 1998, AM J OTOL, V19, P320
[4]   Subretinal electrical stimulation of the rabbit retina [J].
Chow, AY ;
Chow, VY .
NEUROSCIENCE LETTERS, 1997, 225 (01) :13-16
[6]  
CROSBY PA, 1984, ACTA OTO-LARYNGOL, P111
[7]   ANALYSIS OF RESONANT COUPLED COILS IN THE DESIGN OF RADIO-FREQUENCY TRANS-CUTANEOUS LINKS [J].
DONALDSON, ND ;
PERKINS, TA .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1983, 21 (05) :612-627
[8]  
DONALDSON PEK, 1973, IEE P, V120, P281
[9]   Learning retina implants with epiretinal contacts [J].
Eckmiller, R .
OPHTHALMIC RESEARCH, 1997, 29 (05) :281-289
[10]   A computational model of electrical stimulation of the retinal ganglion cell [J].
Greenberg, RJ ;
Velte, TJ ;
Humayun, MS ;
Scarlatis, GN ;
de Juan, E .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1999, 46 (05) :505-514