Evaluation of the permeability and blood-compatibility properties of membranes formed by physical interpenetration of chitosan with PEO/PPO/PEO triblock copolymers

被引:14
作者
Anderson, D [1 ]
Nguyen, T [1 ]
Lai, PK [1 ]
Amiji, M [1 ]
机构
[1] Northeastern Univ, Sch Pharm, Dept Pharmaceut Sci, Boston, MA 02115 USA
关键词
chitosan; PEO/PPO/PEO triblock copolymers; physical interpenetrating network; porous membranes; blood compatibility;
D O I
10.1002/app.1213
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
In order to develop blood compatible membranes with controlled porosity, we have fabricated and examined the properties of physical interpenetrating network (PIN) of chitosan and poly(ethylene oxide)/poly(propylene oxide)/poly(ethylene oxide) (PEO/PPO/PEO) triblock copolymers (Pluronics(R)). Degree of equilibrium swelling, scanning electron microscopy, and electron spectroscopy for chemical analysis (ESCA) were used to characterize the bulk and surface properties. Vitamin B(12) and human serum albumin were used as permeability markers. Platelet adhesion and activation were used to determine the blood-interaction properties of the PIN membranes. Unlike chitosan membranes that were nonporous, the chitosan-Pluronic PIN membranes were highly porous with the pore size, depending on the type of incorporated Pluronic polyol. ESCA results showed a significant increase in the -(C) under bar -O- signal of C1s spectra on the PIN membranes that correlates with the presence of PEO chains on the surface. The permeability coefficients of vitamin B(12) and albumin were higher in the chitosan-Pluronic PIN membranes than in the control. The number of adherent platelets and the extent of activation were significantly reduced on the chitosan-Pluronic PIN membranes. The decrease in platelet adhesion and activation correlated positively with the PEO chain length of the incorporated Pluronic polyols. The results of this study show that chitosan-Pluronic PIN membranes offer a blood-compatible alternative with a higher-molecular-weight cutoff for use in hemodialysis and related applications. (C) 2001 John Wiley & Sons, Inc.
引用
收藏
页码:1274 / 1284
页数:11
相关论文
共 32 条
[1]   SURFACE MODIFICATION BY RADIATION-INDUCED GRAFTING OF PEO/PPO/PEO TRIBLOCK COPOLYMERS [J].
AMIJI, M ;
PARK, K .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1993, 155 (01) :251-255
[2]   PREVENTION OF PROTEIN ADSORPTION AND PLATELET-ADHESION ON SURFACES BY PEO PPO PEO TRIBLOCK COPOLYMERS [J].
AMIJI, M ;
PARK, K .
BIOMATERIALS, 1992, 13 (10) :682-692
[3]  
AMIJI M, 1994, ACS SYM SER, V540, P135
[4]   PERMEABILITY AND BLOOD COMPATIBILITY PROPERTIES OF CHITOSAN-POLY(ETHYLENE OXIDE) BLEND MEMBRANES FOR HEMODIALYSIS [J].
AMIJI, MM .
BIOMATERIALS, 1995, 16 (08) :593-599
[5]   Synthesis of anionic poly(ethylene glycol) derivative for chitosan surface modification in blood-contacting applications [J].
Amiji, MM .
CARBOHYDRATE POLYMERS, 1997, 32 (3-4) :193-199
[6]   Surface modification of chitosan membranes by complexation-interpenetration of anionic polysaccharides for improved blood compatibility in hemodialysis [J].
Amiji, MM .
JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 1996, 8 (04) :281-298
[7]  
AMIJI MM, 1999, RRD POLYM SCI 1, V3, P31
[8]  
ANDERSON J M, 1985, Critical Reviews in Biocompatibility, V1, P111
[9]   HUMAN-PLATELET SPREADING ON SUBSTRATA OF KNOWN SURFACE-CHEMISTRY [J].
BAIER, RE ;
DEPALMA, VA ;
GOUPIL, DW ;
COHEN, E .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1985, 19 (09) :1157-1167
[10]  
BAIER RE, 1978, ARTIF ORGANS, V2, P422