3-D/2-D registration of CT and MR to X-ray images

被引:130
作者
Tomazevic, D [1 ]
Likar, B [1 ]
Slivnik, T [1 ]
Pernus, F [1 ]
机构
[1] Univ Ljubljana, Fac Elect Engn, Ljubljana 1000, Slovenia
关键词
3-D/2-D image registration; computed tomography; gold standard; image-guided therapy; magnetic resonance; spine phantom; X-ray projections;
D O I
10.1109/TMI.2003.819277
中图分类号
TP39 [计算机的应用];
学科分类号
081203 [计算机应用技术]; 0835 [软件工程];
摘要
A crucial part of image-guided therapy is registration of preoperative and intraoperative images, by which the precise position and orientation of the patient's anatomy is determined in three dimensions. This paper presents a novel approach to register three-dimensional (3-D) computed tomography (CT) or magnetic resonance (MR) images to one or more two-dimensional (2-D) X-ray images. The registration is based solely on the information present in 2-D and 3-D images. It does not require fiducial markers, intraoperative X-ray image segmentation, or timely construction of digitally reconstructed radiographs. The originality of the approach is in using normals to bone surfaces, preoperatively defined in 3-D MR or CT data, and gradients of intraoperative X-ray images at locations defined by the X-ray source and 3-D surface points. The registration is concerned with finding the rigid transformation of a CT or MR volume, which provides the best match between surface normals and back projected gradients, considering their amplitudes and orientations. We have thoroughly validated our registration method by using MR, CT, and X-ray images of a cadaveric lumbar spine phantom for which "gold standard" registration was established by means of fiducial markers, and its accuracy assessed by target registration error. Volumes of interest, containing single vertebrae L1-L5, were registered to different pairs of X-ray images from different starting positions, chosen randomly and uniformly around the "gold standard" position. CT/X-ray (MR/X-ray) registration, which is fast, was successful in more than 91% (82% except for L1) of trials if started from the "gold standard" translated or rotated for less than 6 mm or 17degrees (3 mm or 8.6degrees), respectively. Root-mean-square target registration errors were below 0.5 mm for the CT to X-ray registration and below 1.4 mm for MR to X-ray registration.
引用
收藏
页码:1407 / 1416
页数:10
相关论文
共 33 条
[1]
A METHOD FOR REGISTRATION OF 3-D SHAPES [J].
BESL, PJ ;
MCKAY, ND .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (02) :239-256
[2]
BROWN LMG, P IEEE WORKSH MATH M, P42
[3]
Colchester A C, 1996, Med Image Anal, V1, P73, DOI 10.1016/S1361-8415(01)80006-2
[4]
Predicting error in rigid-body point-based registration [J].
Fitzpatrick, JM ;
West, JB ;
Maurer, CR .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (05) :694-702
[5]
The distribution of target registration error in rigid-body point-based registration [J].
Fitzpatrick, JM ;
West, JB .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (09) :917-927
[6]
The process and development of image-guided procedures [J].
Galloway, RL .
ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2001, 3 :83-108
[7]
MULTIDIMENSIONAL TREATMENT PLANNING .2. BEAM EYE-VIEW, BACK PROJECTION, AND PROJECTION THROUGH CT SECTIONS [J].
GOITEIN, M ;
ABRAMS, M ;
ROWELL, D ;
POLLARI, H ;
WILES, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1983, 9 (06) :789-797
[8]
An automatic registration method for frameless stereotaxy, image guided surgery, and enhanced reality visualization [J].
Grimson, WEL ;
Ettinger, GJ ;
White, SJ ;
LozanoPerez, T ;
Wells, WM ;
Kikinis, R .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (02) :129-140
[9]
Providing visual information to validate 2-D to 3-D registration [J].
Guéziec, A ;
Wu, KN ;
Kalvin, A ;
Williamson, B ;
Kazanzides, P ;
Van Vorhis, R .
MEDICAL IMAGE ANALYSIS, 2000, 4 (04) :357-374
[10]
Anatomy-based registration of CT-scan and intraoperative X-ray images for guiding a surgical robot [J].
Guéziec, A ;
Kazanzides, P ;
Williamson, B ;
Taylor, RH .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (05) :715-728