Anisotropic noise propagation in diffusion tensor MRI sampling schemes

被引:121
作者
Batchelor, PG
Atkinson, D
Hill, DLG
Calamante, F
Connelly, A
机构
[1] Kings Coll London, Div Imaging Sci, London SE1 9RT, England
[2] UCL, Inst Child Hlth, Radiol & Phys Unit, London, England
关键词
diffusion encoding; icosahedral; rotational invariance; condition number;
D O I
10.1002/mrm.10491
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The subject of this study is the controversial choice of directions in diffusion tensor MRI (DT-MRI); specifically, the numerical algebra related to this choice. In DT-MRI, apparent diffusivities are sampled in six or more directions and a least-squares equation is solved to reconstruct the diffusion tensor. Numerical characteristics of the system are considered, in particular the condition number and normal matrix, and are shown to be dependent on the relative orientation of the tensor with respect to the laboratory frame. As a consequence, noise propagation can be anisotropic. However, the class of icosahedral radirection schemes is an exception, and icosahedral directions have the same condition number and normal matrix for direction encoding as the ideal scheme with an infinite number of directions. This normal matrix and its condition number are rotationally invariant. Numerical simulations show that for icosahedral schemes with 30 directions the standard deviation of the fractional anisotropy is both low and nearly independent of fiber orientation. The recommended choice of directions for a DT-MRI experiment is therefore the icosahedral set of directions with the highest number of directions achievable in the available time. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:1143 / 1151
页数:9
相关论文
共 25 条
[1]   Theoretical analysis of the effects of noise on diffusion tensor imaging [J].
Anderson, AW .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (06) :1174-1188
[2]  
[Anonymous], 1995, NOTICES AMS
[3]   A simplified method to measure the diffusion tensor from seven MR images [J].
Basser, PJ ;
Pierpaoli, C .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (06) :928-934
[4]   ESTIMATION OF THE EFFECTIVE SELF-DIFFUSION TENSOR FROM THE NMR SPIN-ECHO [J].
BASSER, PJ ;
MATTIELLO, J ;
LEBIHAN, D .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1994, 103 (03) :247-254
[5]  
Basser PJ, 2000, MAGNET RESON MED, V44, P41, DOI 10.1002/1522-2594(200007)44:1<41::AID-MRM8>3.0.CO
[6]  
2-O
[7]  
BERGER M, 1980, GEOMETRY, V2
[8]  
Clark CA, 2000, MAGN RESON MED, V44, P852, DOI 10.1002/1522-2594(200012)44:6<852::AID-MRM5>3.0.CO
[9]  
2-A
[10]  
CUI J, 1997, SIAM J SCI COMPUT, P8