Computations of SAR distributions for two anatomically based models of the human head using CAD files of commercial telephones and the parallelized FDTD code

被引:70
作者
Tinniswood, AD [1 ]
Furse, CM [1 ]
Gandhi, OP [1 ]
机构
[1] Univ Utah, Dept Elect Engn, Salt Lake City, UT 84112 USA
关键词
D O I
10.1109/8.686769
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A method for importing data from computer-aided design (CAD) files for a mobile telephone into finite-difference time-domain (FDTD) simulation software is described. Although the FDTD method is well suited for the bio-electromagnetic simulations and has become the method of choice for most researchers in this area, there may be some limitations to its use. Limitations include, the description of the source (e.g., the mobile telephone) and the fact that the FDTD method requires large amounts of memory and computational power. The size of the computational space is dependent upon both the physical size of the model and its resolution. Higher frequencies of operation require higher resolutions. This could place the solution of some problems outside the capabilities of the technique. Often the telephone has to be represented by a plastic covered metal box, which approximates the shape of the actual device. The paper addresses these problems, Wires and circuit boards inside the telephone can act as resonant elements if they are not shielded, This potential problem is also considered. The large problem size associated with high-resolution FDTD simulations is accommodated by the use of a parallel implementation of the FDTD method (run on an IBM SP-2), The techniques developed here are used for two anatomically based head models that have been developed from magnetic resonance imaging (MRI) of two human subjects, The usefulness of the techniques developed and comparisons of the specific absorption rates (SAR's) in the two models are discussed.
引用
收藏
页码:829 / 833
页数:5
相关论文
共 13 条
[1]  
*ANSI IEEE, 1992, C9511992 ANSI IEEE
[2]   SAR CALCULATIONS IN AN ANATOMICALLY REALISTIC MODEL OF THE HEAD FOR MOBILE COMMUNICATION TRANSCEIVERS AT 900-MHZ AND 1.8-GHZ [J].
DIMBYLOW, PJ ;
MANN, SM .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (10) :1537-1553
[3]  
Federal Communications Commission, 1996, 96326 FCC
[4]  
Gabriel C, 1996, ALOETR19960037 RFR D
[5]   SOME NUMERICAL-METHODS FOR DOSIMETRY - EXTREMELY LOW-FREQUENCIES TO MICROWAVE-FREQUENCIES [J].
GANDHI, OP .
RADIO SCIENCE, 1995, 30 (01) :161-177
[6]   Electromagnetic absorption in the human head and neck for mobile telephones at 835 and 1900 MHz [J].
Gandhi, OP ;
Lazzi, G ;
Furse, CM .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1996, 44 (10) :1884-1897
[7]   Electromagnetic absorption in the human head from experimental 6-GHz handheld transceivers [J].
Gandhi, OP ;
Chen, JY .
IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 1995, 37 (04) :547-558
[8]  
GANDHI OP, 1994, P INT S EL COMP ROM, P1
[9]  
*IRCP, 1992, IRCP PUBL, V23
[10]   EM INTERACTION OF HANDSET ANTENNAS AND A HUMAN IN PERSONAL COMMUNICATIONS [J].
JENSEN, MA ;
RAHMATSAMII, Y .
PROCEEDINGS OF THE IEEE, 1995, 83 (01) :7-17