FLAIR imaging in the follow-up of low-grade gliomas: time to dispense with the dual-echo?

被引:29
作者
Bynevelt, M
Britton, J
Seymour, H
MacSweeney, E
Thomas, N
Sandhu, K
机构
[1] Arkinson Morleys Hosp, Dept Neuroradiol, London SW20 0NE, England
[2] Atkinson Morleys Hosp, Dept Neurosurg, London SW20 0NE, England
关键词
glioma; low-grade; magnetic resonance imaging; pulse sequences;
D O I
10.1007/s002340000389
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Fluid-attenuated inversion-recovery (FLAIR) imaging has established its utility in neuroimaging. We propose this imaging sequence as a replacement for proton density (PD) and T2-weighted spin-echo sequences in the follow-up of low-grade glioma. 26 MRI examinations of 18 patients with such tumours were reviewed by three neuroradiologists and a neurosurgeon. FLAIR was found to be superior for appreciation of the lesion (91% of studies) and for demonstration of its margin (92 %). FLAIR was also better at showing different tumour components, particularly in regions difficult to demonstrate in some planes, such as the vertex in axial imaging. The sequence also defines the postoperative cavity, shows the least amount of susceptibility effect associated with surgical clips, and demonstrates local spread (to white matter tracts, subependymal and capsular) more distinctly. We conclude that FLAIR can replace PD and T2-weighted spin-echo imaging in radiological follow-up of low-grade glioma.
引用
收藏
页码:129 / 133
页数:5
相关论文
共 14 条
[1]   MRI OF THE BRAIN-STEM USING FLUID ATTENUATED INVERSION RECIVERY PULSE SEQUENCES [J].
DECOENE, B ;
HAJNAL, JV ;
PENNOCK, JM ;
BYDDER, GM .
NEURORADIOLOGY, 1993, 35 (05) :327-331
[2]  
DECOENE B, 1992, AM J NEURORADIOL, V13, P1555
[3]   USE OF FLUID ATTENUATED INVERSION RECOVERY (FLAIR) PULSE SEQUENCES IN MRI OF THE BRAIN [J].
HAJNAL, JV ;
BRYANT, DJ ;
KASUBOSKI, L ;
PATTANY, PM ;
DECOENE, B ;
LEWIS, PD ;
PENNOCK, JM ;
OATRIDGE, A ;
YOUNG, IR ;
BYDDER, GM .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1992, 16 (06) :841-844
[4]   Fast flair imaging of the brain using the fast spin-echo and gradient spin-echo technique [J].
Hittmair, K ;
Umek, W ;
Schindler, EG ;
BaSsalamah, A ;
Pretterklieber, ML ;
Herold, CJ .
MAGNETIC RESONANCE IMAGING, 1997, 15 (04) :405-414
[5]  
Kates R, 1996, Top Magn Reson Imaging, V8, P389
[6]   IMAGING-BASED STEREOTAXIC SERIAL BIOPSIES IN UNTREATED INTRACRANIAL GLIAL NEOPLASMS [J].
KELLY, PJ ;
DAUMASDUPORT, C ;
KISPERT, DB ;
KALL, BA ;
SCHEITHAUER, BW ;
ILLIG, JJ .
JOURNAL OF NEUROSURGERY, 1987, 66 (06) :865-874
[7]  
KOVUKANGA J, 1995, MALIGNANT BRAIN TUMO, P151
[8]  
Laws E R Jr, 1986, Clin Neurosurg, V33, P575
[9]  
MATTHEWS VP, 1988, MRI CLIN N AM, V6, P53
[10]  
MCCORMACK BM, 1992, NEUROSURGERY, V31, P636