Improved nerve cuff electrode recordings with subthreshold anodic currents

被引:17
作者
Sahin, M [1 ]
Durand, DM [1 ]
机构
[1] Case Western Reserve Univ, Dept Biomed Engn, Ctr Neural Engn, Cleveland, OH 44106 USA
关键词
active membrane models; cable model; compound action potentials; cuff electrodes; extracellular potentials; hyperpolarization; nerve simulation; propagation velocity; whole nerve recording;
D O I
10.1109/10.704873
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A method has been developed for improving the signal amplitudes of the recordings obtained with nerve cuff electrodes, The amplitude of the electroneurogram (ENG) has been shown to increase with increasing distance between the contacts when cuff electrodes are used to record peripheral nerve activity [9]. The effect is directly related to the propagation speed of the action potentials. Computer simulations have shown that the propagation velocity of action potentials in a length of a nerve axon can be decreased by subthreshold extracellular anodic currents. Slowing the action potentials is analogous to increasing the cuff length in that both result in longer intercontact delays, thus, larger signal outputs. This phenomenon is used to increase the amplitudes of whole nerve recordings obtained with a short cuff electrode. Computer simulations predicting the slowing effect of anodic currents as well as the experimental verification of this effect are presented. The increase in the amplitude of compound action potentials (CAP's) is demonstrated experimentally in an in vitro preparation. This method can be used to improve the signal-to-noise ratios when recording from short nerve segments where the cuff length is limited.
引用
收藏
页码:1044 / 1050
页数:7
相关论文
共 13 条
[1]   Slip information provided by nerve cuff signals: application in closed-loop control of functional electrical stimulation [J].
Haugland, Morten K. ;
Hoffer, J.Andy .
IEEE Transactions on Rehabilitation Engineering, 1994, 2 (01) :29-36
[2]  
Haugland M. K., 1995, IEEE Transactions on Rehabilitation Engineering, V3, P307, DOI 10.1109/86.481970
[3]   A PROGRAM FOR SIMULATION OF NERVE EQUATIONS WITH BRANCHING GEOMETRIES [J].
HINES, M .
INTERNATIONAL JOURNAL OF BIO-MEDICAL COMPUTING, 1989, 24 (01) :55-68
[4]   ANALYSIS OF A MODEL FOR EXCITATION OF MYELINATED NERVE [J].
MCNEAL, DR .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1976, 23 (04) :329-337
[5]   INSTRUMENTATION FOR ENG AND EMG RECORDINGS IN FES SYSTEMS [J].
NIKOLIC, ZM ;
POPOVIC, DB ;
STEIN, RB ;
KENWELL, Z .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1994, 41 (07) :703-706
[6]   SENSORY NERVE RECORDING FOR CLOSED-LOOP CONTROL TO RESTORE MOTOR FUNCTIONS [J].
POPOVIC, DB ;
STEIN, RB ;
JOVANOVIC, KL ;
DAI, RC ;
KOSTOV, A ;
ARMSTRONG, WW .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1993, 40 (10) :1024-1031
[7]  
SAHIN M, 1995, P IEEE 17 ANN C ENG
[8]   DIFFERENTIAL BLOCKING OF MYELINATED NERVE FIBERS BY TRANSIENT DEPOLARIZATION [J].
SASSEN, M ;
ZIMMERMANN, M .
PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1973, 341 (03) :179-195
[9]  
Stein R B, 1975, Can J Neurol Sci, V2, P235
[10]   STABLE LONG-TERM RECORDINGS FROM CAT PERIPHERAL-NERVES [J].
STEIN, RB ;
NICHOLS, TR ;
JHAMANDAS, J ;
DAVIS, L ;
CHARLES, D .
BRAIN RESEARCH, 1977, 128 (01) :21-38