MR imaging contrast in human brain tissue: Assessment and optimization at 4 T

被引:49
作者
Duewell, S [1 ]
Wolff, SD [1 ]
Wen, H [1 ]
Balaban, RS [1 ]
Jezzard, P [1 ]
机构
[1] NHLBI,CARDIAC ENERGET LAB,BETHESDA,MD 20892
关键词
brain; MR; magnetic resonance (MR); high-field-strength imaging; pulse sequences; relaxometry;
D O I
10.1148/radiology.199.3.8638005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate multiple magnetic resonance (MR) imaging sequences for their ability to provide T1- and T2-weighted images at a field strength of 4 T, and to validate previously obtained relaxation time measurements. MATERIALS AND METHODS: Different spin-echo, inversion-recovery (IR), gradient-recalled acquisition in the steady state (GRASS), and magnetization transfer contrast-enhanced GRASS sequences were evaluated in a single section, each in at least four volunteers. Also, interleaved echo-planar imaging (IEPI) and interleaved gradient-recalled echo (IGRE) sequences were analyzed and compared with standard sequences. RESULTS: Predicted contrast behavior, according to MR relaxation time measurements, was found to agree well with that of the validation experiments. Fair T1 contrast can be achieved on MR images at 4 T, contrary to early predictions. Under other conditions, however, such as partially spin-density-weighted parameters, lower contrast is observed at the high field strength when compared with conventional field strengths. CONCLUSION: The longer T1 values at higher field strengths have a substantial effect on image contrast. Depending on the sequence and parameters chosen, good image contrast can be realized at 4 T. IEPI and hybrid IR IGRE sequences are useful in shortening the prolonged examination times owing to the longer T1 values at higher field strengths.
引用
收藏
页码:780 / 786
页数:7
相关论文
共 30 条
[1]  
BALABAN RS, 1994, P SOC MAGN RESON, V1, P561
[2]   WHOLE-BODY MR IMAGING AND SPECTROSCOPY WITH A 4-T SYSTEM [J].
BARFUSS, H ;
FISCHER, H ;
HENTSCHEL, D ;
LADEBECK, R ;
VETTER, J .
RADIOLOGY, 1988, 169 (03) :811-816
[3]  
BENDALL MR, 1987, MAGNET RESON MED, V4, P493
[4]  
BOTTOMLEY PA, 1984, MED PHYS, V11, P425, DOI 10.1118/1.595535
[5]   T1 AND T2 MEASUREMENTS ON A 1.5-T COMMERCIAL MR IMAGER [J].
BREGER, RK ;
RIMM, AA ;
FISCHER, ME ;
PAPKE, RA ;
HAUGHTON, VM .
RADIOLOGY, 1989, 171 (01) :273-276
[6]   REPRODUCIBILITY OF RELAXATION AND SPIN-DENSITY PARAMETERS IN PHANTOMS AND THE HUMAN-BRAIN MEASURED BY MR IMAGING AT 1.5-T [J].
BREGER, RK ;
WEHRLI, FW ;
CHARLES, HC ;
MACFALL, JR ;
HAUGHTON, VM .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (05) :649-662
[7]   THE FIELD-DEPENDENCE OF NMR IMAGING .1. LABORATORY ASSESSMENT OF SIGNAL-TO-NOISE RATIO AND POWER DEPOSITION [J].
CHEN, CN ;
SANK, VJ ;
COHEN, SM ;
HOULT, DI .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (05) :722-729
[8]   MUSCULOSKELETAL MR-IMAGING AT 4 T AND AT 1.5 T - COMPARISON OF RELAXATION-TIMES AND IMAGE-CONTRAST [J].
DUEWELL, SH ;
CECKLER, TL ;
ONG, K ;
WEN, H ;
JAFFER, FA ;
CHESNICK, SA ;
BALABAN, RS .
RADIOLOGY, 1995, 196 (02) :551-555
[9]   THE UNCOMMON LONGITUDINAL RELAXATION DISPERSION OF HUMAN-BRAIN WHITE MATTER [J].
FISCHER, HW ;
VANHAVERBEKE, Y ;
SCHMITZFEUERHAKE, I ;
MULLER, RN .
MAGNETIC RESONANCE IN MEDICINE, 1989, 9 (03) :441-446
[10]   RAPID NMR IMAGING OF DYNAMIC PROCESSES USING THE FLASH TECHNIQUE [J].
FRAHM, J ;
HAASE, A ;
MATTHAEI, D .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (02) :321-327