A cost-effectiveness analysis of the use of a mechanical barrier system to reduce the risk of mistransfusion

被引:42
作者
AuBuchon, JP [1 ]
Littenberg, B [1 ]
机构
[1] DARTMOUTH COLL,HITCHCOCK MED CTR,DEPT PATHOL,LEBANON,NH 03756
关键词
D O I
10.1046/j.1537-2995.1996.36396182139.x
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Background: A blood component is transfused to a patient other than the intended recipient because of patient and sample identification problems once in about every 24,000 transfusions. An investigation was performed of the cost-effectiveness of a barrier system to prevent mistransfusion of a unit of red cells through this kind of error. Study Design and Methods: A decision analysis model was constructed that took into account nonfatal and fatal events, costs of patient care, and legal costs. The model was used to determine the cost-effectiveness of the barrier system in terms of cost per year of life saved and lives saved per million transfusions. Results: The barrier system is predicted to save 1.5 lives per million transfusions when used as intended. If the cost-effectiveness calculations are based on an average damage award for a fatality of more than $725,000 and a chance of mistransfusion exceeding 1 in 16,700, use of;the system results in reduced healthcare expenditures. If no legal costs are included in the cost-effectiveness calculations, use of the system costs $197,000 per year of life saved. Routine use of the system extends patient life by 1 year per 60,000 units transfused. Conclusion: The application of a barrier system to prevent mistransfusion and related morbidity and mortality can be cost-effective. If legal costs are included in the calculations, the use of a barrier system reduces total costs.
引用
收藏
页码:222 / 226
页数:5
相关论文
共 30 条
[1]
Aubuchon J. P., 1995, Transfusion (Bethesda), V35, p43S
[2]
SAFETY AND COST-EFFECTIVENESS OF SOLVENT-DETERGENT-TREATED PLASMA - IN SEARCH OF A ZERO-RISK BLOOD-SUPPLY [J].
AUBUCHON, JP ;
BIRKMEYER, JD .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1994, 272 (15) :1210-1214
[3]
BEDSIDE TRANSFUSION ERRORS - A PROSPECTIVE SURVEY BY THE BELGIUM SANGUIS GROUP [J].
BAELE, PL ;
DEBRUYERE, M ;
DENEYS, V ;
DUPONT, E ;
FLAMENT, J ;
LAMBERMONT, M ;
LATINNE, D ;
STEENSENS, L ;
VANCAMP, B ;
WATERLOOS, H .
VOX SANGUINIS, 1994, 66 (02) :117-121
[4]
BAKER RJ, 1969, ANN SURG, P684
[5]
A CONVENIENT APPROXIMATION OF LIFE EXPECTANCY (THE DEALE) .1. VALIDATION OF THE METHOD [J].
BECK, JR ;
KASSIRER, JP ;
PAUKER, SG .
AMERICAN JOURNAL OF MEDICINE, 1982, 73 (06) :883-888
[6]
A CONVENIENT APPROXIMATION OF LIFE EXPECTANCY (THE DEALE) .2. USE IN MEDICAL DECISION-MAKING [J].
BECK, JR ;
PAUKER, SG ;
GOTTLIEB, JE ;
KLEIN, K ;
KASSIRER, JP .
AMERICAN JOURNAL OF MEDICINE, 1982, 73 (06) :889-897
[7]
BINDER LS, 1959, SURG GYNECOL OBSTET, V108, P19
[8]
THE COST-EFFECTIVENESS OF PREOPERATIVE AUTOLOGOUS BLOOD DONATION FOR TOTAL HIP AND KNEE REPLACEMENT [J].
BIRKMEYER, JD ;
GOODNOUGH, LT ;
AUBUCHON, JP ;
NOORDSIJ, PG ;
LITTENBERG, B .
TRANSFUSION, 1993, 33 (07) :544-551
[9]
COST-EFFECTIVENESS OF PREOPERATIVE AUTOLOGOUS DONATION IN CORONARY-ARTERY BYPASS-GRAFTING [J].
BIRKMEYER, JD ;
AUBUCHON, JP ;
LITTENBERG, B ;
OCONNOR, GT ;
NEASE, RF ;
NUGENT, WC ;
GOODNOUGH, LT .
ANNALS OF THORACIC SURGERY, 1994, 57 (01) :161-169