PURPOSE: To compare examination time with radiologist time and to measure radiation dose of computed tomographic (CT) fluoroscopy, conventional CT, and conventional fluoroscopy as guiding modalities for shoulder CT arthrography. MATERIALS AND METHODS: Glenohumeral injection of contrast material for CT arthrography was performed in 64 consecutive patients (mean age, 32 years; age range, 16-74 years) and was guided with CT fluoroscopy (n = 28), conventional CT (n = 14), or conventional fluoroscopy (n = 22). Room times (arthrography, room change, CT, and total examination times) and radiologist times (time the radiologist spent in the fluoroscopy or CT room) were measured. One-way analysis of variance and Bonferroni-Dunn posthoc tests were per-formed for comparison of mean times. Mean effective radiation dose was calculated for each method with examination data, phantom measurements, and standard software. RESULTS: Mean total examination time was 28.0 minutes for CT fluoroscopy, 28.6 minutes for conventional CT, and 29.4 minutes for conventional fluoroscopy; mean radiologist time was 9.9 minutes, 10.5 minutes, and 9.0 minutes, respectively. These differences were not statistically significant. Mean effective radiation dose was 0.0015 mSv for conventional fluoroscopy (mean, nine sections), 0.22 mSv for CT fluoroscopy (120 W; 50 mA; mean, 15 sections), and 0.96 mSv for conventional CT (140 W; 240 mA; mean, six sections). Effective radiation dose can be reduced to 0.18 mSv for conventional CT by changing imaging parameters to 120 kV and 100 mA. Mean effective radiation dose of the diagnostic CT arthrographic examination (140 W; 240 mA; mean, 25 sections) was 2.4 mSv. CONCLUSION: CT fluoroscopy and conventional CT are valuable alternative modalities for glenohumeral CT arthrography, as examination and radiologist times are not significantly different. CT guidance requires a greater radiation dose than does conventional fluoroscopy, but with adequate parameters CT guidance constitutes approximately 8% of the radiation dose. (C) RSNA, 2003.
引用
收藏
页码:153 / 158
页数:6
相关论文
共 26 条
[1]  
[Anonymous], 61267 IEC
[2]   Benefits and safety of CT fluoroscopy in interventional radiologic procedures [J].
Carlson, SK ;
Bender, CE ;
Classic, KL ;
Zink, FE ;
Quam, JP ;
Ward, EM ;
Oberg, AL .
RADIOLOGY, 2001, 219 (02) :515-520
[3]   Real-time CT fluoroscopy: Evolution of an interventional tool [J].
Daly, B ;
Templeton, PA .
RADIOLOGY, 1999, 211 (02) :309-315
[4]   Real time CT-fluoroscopy: diagnostic and therapeutic applications [J].
de Mey, J ;
Op de Beeck, B ;
Meysman, M ;
Noppen, M ;
De Maeseneer, M ;
Vanhoey, M ;
Vincken, W ;
Osteaux, M .
EUROPEAN JOURNAL OF RADIOLOGY, 2000, 34 (01) :32-40
[5]   Near real-time CT fluoroscopy using computer automated scan technology in nonvascular interventional procedures [J].
Ernst, RD ;
Kim, HS ;
Kawashima, A ;
Middlebrook, MR ;
Sandler, CM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (02) :319-321
[6]   Real-time CT-fluoroscopy for guidance of percutaneous drainage procedures [J].
Froelich, JJ ;
Saar, B ;
Hoppe, M ;
Ishaque, N ;
Walthers, EM ;
Regn, J ;
Klose, KJ .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1998, 9 (05) :735-740
[7]   Effect of the learning process on procedure times and radiation exposure for CT fluoroscopy-guided percutaneous biopsy procedures [J].
Gianfelice, D ;
Lepanto, L ;
Perreault, P ;
Chartrand-Lefebvre, C ;
Milette, PC .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2000, 11 (09) :1217-1221
[8]   Value of CT fluoroscopy for percutaneous biopsy procedures [J].
Gianfelice, D ;
Lepanto, L ;
Perreault, P ;
Chartrand-Lefebvre, C ;
Milette, PC .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2000, 11 (07) :879-884
[9]   PRECISE BIOPSY LOCALIZATION BY COMPUTED TOMOGRAPHY [J].
HAAGA, JR ;
ALFIDI, RJ .
RADIOLOGY, 1976, 118 (03) :603-607
[10]   Computed tomographic fluoroscopy-guided transthoracic needle biopsy for diagnosis of pulmonary nodules [J].
Hirose, T ;
Mori, K ;
Machida, S ;
Tominaga, K ;
Yokoi, K ;
Adachi, M .
JAPANESE JOURNAL OF CLINICAL ONCOLOGY, 2000, 30 (06) :259-262